检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:侯超[1,3] 李伟钊 张冲[1] 杨鲁伟[1,2] 张桂兰[1] 孙椰望 魏娟[1] HOU Chao;LI Wei-zhao;ZHANG Chong;YANG Lu-wei;ZHANG Gui-lan;SUN Ye-wang;WEI Juan(Technical Institute of Physics and Chemistry,Chinese Academy of Sciences,Beijing 100190,China;University of Chinese Academy of Sciences,Beijing 100049,China;China Nuclear Power Engineering Co.,Ltd.,Beijing 100840,China)
机构地区:[1]中国科学院理化技术研究所,北京100190 [2]中国科学院大学,北京100049 [3]中国核电工程有限公司,北京100840
出 处:《现代化工》2024年第11期196-201,共6页Modern Chemical Industry
基 金:科工局乏燃料后处理专项;周远院士工作站专项(SZ20211166)。
摘 要:为验证多相流热泵蒸发系统的在线阻垢及强化换热性能,以蒸氨废液为液相工质、氧化铝及聚甲醛粒子为阻垢颗粒进行实验研究。结果表明,氧化铝颗粒的加入可有效去除蒸发器已有垢层,换热系数由结垢后的392.5 W/(m^(2)·K)提升至1 712.2 W/(m^(2)·K),且连续运行130 h换热系数未降低;蒸发器换热系数受颗粒物性参数影响较大,随着颗粒直径、密度、体积分率增加换热系数逐渐增大,但增加过量时导致流动不畅,换热系数降低;颗粒自身材质导热系数越高强化换热效果越好;循环流量、颗粒分布形式对换热系数也有较大影响,提高循环流量有助于强化换热;不同分布形式在一定程度上均可提高换热系数,双层多孔分布器可实现颗粒逐级输运,增加其进入换热管比例,强化换热效果最佳。The online scale inhibition and enhanced heat transfer performances of a set of multi-phase flow heat pump evaporation system is verified through employing ammonia-evaporated waste liquid as the liquid material,and using alumina and polyoxymethylene as the solid scaling particles.It is verified by results that the existing scale layer can be removed effectively after adding alumina particles,and the heat transfer coefficient of the evaporator is improved from 392.5 W/(m^(2)·K)after scaling to 1712.2 W/(m^(2)·K).As descaling by alumina particles,the heat transfer coefficient remains unchanged after 130 h of continuous operation.The heat transfer coefficient of the evaporator is greatly affected by the property parameters of solid particles.With the increases of the diameter,density,type,and volume fraction of solid particles,the heat transfer coefficient increases as well.However,the fluidization state will be weakened and the heat transfer coefficient will decrease consequently when these parameters increase excessively.The higher the thermal conductivity of the particles,the better the heat transfer enhancement effect.Moreover,circulation flowrate and particle distribution form have also big impact on the heat transfer coefficient of the evaporator.Increasing the circulation flowrate contributes to enhancing the heat transfer effect.Different particle distribution forms are beneficial to improve the heat transfer coefficient,in which double-layer perforated plate distributor can also facilitate particle transportation,which is helpful to enhance the proportion of particles entering heat exchange tubes and hence presents a better heat transfer enhancement effect.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:3.22.117.210