变换装置脱盐水换热器腐蚀原因分析  被引量:1

Analysis of corrosion causes of desalinated water heat exchanger in conversion device

在线阅读下载全文

作  者:韩帅 赵林涛 崔玉彪 蒋永刚 HAN Shuai;ZHAO Lintao;CUI Yubiao;JIANG Yonggang(Jiangxi Xinlianxin Chemical Industry Co.,Ltd.Jiujiang 332000,Jiangxi Province)

机构地区:[1]江西心连心化学工业股份有限公司,江西九江332000

出  处:《氮肥技术》2024年第5期31-32,共2页Nitrogenous Fertilizer Technology

摘  要:CO变换汽提塔出气冷却换热器与脱盐水换热进行降温,在运行过程中此换热器经常出现泄漏等问题。本文分析了汽提塔出气各种成分对换热管材质的腐蚀机理,并根据其特点提出相应的处理措施。The cooling heat exchanger for the outlet of the CO conversion stripping tower,which exchanges heat with desalinated water for cooling,The heat exchanger often leaks and other problems during operation.This article analyzes the corrosion mechanism of various components in the exhaust gas of the stripping tower on the material of heat transfer tubes,and proposes corresponding treatment measure based on their characteristics.

关 键 词:脱盐水换热器 腐蚀 原因 措施 

分 类 号:TQ050.9[化学工程]

 