柔性直流输电系统在低短路比下的功率运行区间控制方法  被引量:2

A Power Operation Interval Control Method for Flexible DC Transmission System under Low Short-Circuit Ratio

在线阅读下载全文

作  者:王帆 赵路新 路鹏程 连浩然 陈云辉 范宏 田书欣 刘琳琳 WANG Fan;ZHAO Luxin;LU Pengcheng;LIAN Haoran;CHEN Yunhui;FAN Hong;TIAN Shuxin;LIU Linlin(State Grid Xiong'an New Area Power Supply Company,Baoding 071700,Hebei,China;Shanghai Electric Power Design Institute Co.,Ltd.,Shanghai 200025,China;Shanghai University of Electric Power,Shanghai 200090,China)

机构地区:[1]国网雄安新区供电公司,河北保定071700 [2]上海电力设计院有限公司,上海200025 [3]上海电力大学,上海200090

出  处:《电网与清洁能源》2024年第9期13-20,共8页Power System and Clean Energy

基  金:上海市2022年度“科技创新行动计划”科技支撑碳达峰碳中和专项项目(22DZ1206100)。

摘  要:深入探讨柔性直流输电系统的功率运行区间控制策略,对于提高电能传输质量并保障系统稳定至关重要。在此背景下,提出了一种柔性直流输电系统在低短路比下的功率运行区间控制方法。首先,分析低短路比条件下柔性直流系统的功率运行特性和影响因素,并确定了限制模块化多电平换流器的柔性直流输电(modular multilevel converter-high voltage direct current,MMC-HVDC)稳态运行区域的约束条件。然后,基于这些约束条件,构建了柔性直流输电系统在低短路比下的功率运行区间的理论计算模型,并开发了低短路比柔性直流系统和弱交流系统相连的柔性系统功率运行范围的计算程序。最后,在仿真环境中使用逐点扫描法和隐函数绘图法绘制了MMC在PQ平面上的稳态运行区域的边界,互相印证计算结果的准确性,同时证实了所提控制方法的有效性。Thoroughly exploring the power operation interval control strategy of flexible DC transmission systems is crucial for improving the quality of power transmission and ensuring system stability.In this context,this paper proposes a power operation interval control method for flexible DC transmission system under low short-circuit ratio.Firstly,the power operation characteristics and influencing factors of the flexible DC system under the condition of low short-circuit ratio are analyzed,and the constraints that limit the steady-state operation area of the flexible DC transmission of the modular multilevel converter-high voltage direct current(MMC-HVDC)are determined.Secondly,based on these constraints,a theoretical calculation model of the power operation interval of the flexible DC transmission system under low short-circuit ratio is constructed,and the calculation program of the power operating range of the flexible system connected by the flexible DC system with low short-circuit ratio and the weak AC system is developed.Finally,the boundary of the steady-state operation region of MMC on the PQ plane is drawn by using the point-by-point scanning method and the implicit function plotting method in the simulation environment to mutually the accuracy of the calculation results and verify the effectiveness of the proposed control method.

关 键 词:柔性直流输电 稳态运行范围 模块化多电平换流器 短路比 

分 类 号:TM72[电气工程—电力系统及自动化]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象