检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:洪晓彤 刘海静 HONG Xiaotong;LIU Haijing(Foshan Power Supply Bureau of Guangdong Power Grid Co.,Ltd.,Foshan 528000)
机构地区:[1]广东电网有限责任公司佛山供电局,广东佛山528000
出 处:《电力安全技术》2024年第10期41-45,共5页Electric Safety Technology
摘 要:介绍了单相、三相变压器直流法测试绕组极性两种组别试验方法,以YN,y12和YN,d11两种接线组别为例对直流法测量变压器的原理进行分析,通过向量分解法探究极性组合与向量图的对应关系,找出直流法与向量分解法之间的联系和规律,确保了变压器组别判定的正确性。Two types of group test methods are introduced for measuring the polarity of windings of single-phase and three-phase transformers based on the DC method.Taking two wiring groups(YN,y12 and YN,d11)as an example,analysis is conducted on the principle of DC method transformer measurement,the correspondence of polarity combination and vector graphs based on the vector decomposition method are investigated,and the relationship and the laws between the DC method and the vector deposition method is found out,which ensures the correctness of identifying the transformer groups.