液气比对湿法脱硫系统能耗的影响及节能潜力分析  

Effects of Liquid-gas Ratio on Energy Consumption of Wet Desulfurization System and Analysis of Energy-saving Potential

在线阅读下载全文

作  者:张天泉 李德武 邱艺雄 范日新 ZHANG Tianquan;LI Dewu;QIU Yixiong;FAN Rixin(Guangdong Yuedian Bohe Energy Co.,Ltd.,Maoming 525000;Guangzhou Yueneng Electric Power Technology Development Co.,Ltd.,Guangzhou 510000)

机构地区:[1]广东粤电博贺能源有限公司,广东茂名525000 [2]广州粤能电力科技开发有限公司,广东广州510000

出  处:《电力安全技术》2024年第10期72-74,共3页Electric Safety Technology

摘  要:基于某1000MW级燃煤电厂1号机组实际运行中的大量数据,探讨了液气比对脱硫效率和电耗能的影响;运用正态分布统计分析,探索机组控制净烟气SO_(2)平均浓度在23mg/m^(3)左右时所需的液气比大小和对应的pH值,讨论液气比对脱硫能耗的影响及节能潜力,得出将液气比控制在合理的范围内可以达到良好节能效果的结论。Based on the massive data of Unit 1 in the operation of a 1000 MW coal-fired power plant,the effects of liquid-gas ratio on desulfurization efficiency and power consumption is discussed.Normal distribution statistical analysis is adopted to explore the required liquid-gas ratio and the corresponding pH value for controlling the average concentration of SO_(2) in the net flue gas of the unit at around 23 mg/m^(3),and the effects of liquid-gas ratio on desulfurization energy consumption and energy-saving potential are also discussed.It comes to a conclusion that controlling the liquid-gas ratio within a reasonable range is available to achieve sound energy-saving effects.

关 键 词:湿法脱硫 脱硫效率 液气比 脱硫能耗 

分 类 号:TM621[电气工程—电力系统及自动化]

 