一种363 kV GIS配电装置几字弯母线的布置方案  

A layout scheme characterized by a double-bent shaped bus duct for the 363 kV GIS distribution device

在线阅读下载全文

作  者:王金有 WANG Jinyou(Ningxia Ningdian Electric Power Design Co.,Ltd.,Yinchuan Ningxia 750004,China)

机构地区:[1]宁夏宁电电力设计有限公司,宁夏银川750004

出  处:《宁夏电力》2024年第5期37-42,共6页Ningxia Electric Power

摘  要:在气体绝缘金属封闭开关设备(gas insulated switchgear,GIS)的建设过程中,GIS母线需要水平放置,当站区带有坡度时,在坡底处需要通过加高设备基础来抬高母线,以保证母线水平。当站区面积较大时,坡底处的设备基础过高,给运检带来困难且严重影响美观,因此,提出一种363 kV GIS母线筒几字弯布置方案,有效解决此问题,为其他工程提供参考。During the construction of a gas-insulated switchgear(GIS),the GIS busbar needs to be placed horizontally.When the substation area is on a slope,the busbars at the lower end of the slope must be raised by elevating the equipment foundation to keep them level.In larger substations,excessively high equipment foundations at the lower end of the slope can complicate operations and inspections and significantly affect aesthetics.This paper proposes a layout scheme characterized by a double-bent shaped busbar duct for the 363 kV GIS,which effectively addresses this problem and provides a reference for similar projects.

关 键 词:363 kV GIS 站区坡度 母线筒几字弯 Z字型母线筒 

分 类 号:TM595[电气工程—电器]

 