检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:陈梦楠 CHEN Mengnan(State Grid Jiangsu Power Co.,Ltd.Guanyun County Power Supply Branch,Lianyungang 222200,China)
机构地区:[1]国网江苏省电力有限公司灌云县供电分公司,江苏连云港222200
出 处:《电工技术》2024年第19期122-124,共3页Electric Engineering
摘 要:自动告警是变电站自动化监测系统的关键功能,但现有方法的漏报率和虚警率较高,难以实现精准告警。为此,提出了一种基于网络监控技术的变电站运行异常状态自动告警方法。通过多簇划分将变电站分为多个异构监控区域,利用无线网络传输异常变量数据,并采用RVM算法进行数据分类和异常特征提取,最后通过可靠性模型识别异常状态并发出告警。实验结果显示,该方法的漏报率和虚警率均低于1%,在变电站自动化监测领域展现出广阔的应用前景。Automatic alarm is a key function of substation automatic monitoring system,but currently prevailing methods are inferior in accuracy due to high false negative ratios and false alarm ratios.The present work made a preliminary attempt to establish a network monitoring-based method for the automatic alarm of operational abnormal states.The method divides the substation into multiple heterogeneous monitoring areas through multi cluster partitioning,uses wireless network to transmit abnormal variable data,utilizes RVM algorithm for data classification and abnormal feature extraction,and identify and alarms against operational abnormal states through reliability model.The method was experimentally indicated to achieve a false negative ratio and a false alarm ratio both below 1%,and hence to have a potential applicative prospect in the field of substation automatic monitoring.
关 键 词:网络监控 变电站 异常状态 自动告警 RVM算法 可靠性模型
分 类 号:TM732[电气工程—电力系统及自动化]