作 者:张玉树 姜晓峰[2] 文振明 孙凤举[2] 刘彦博 降宏瑜 邱爱慈[1,2] Zhang Yushu;Jiang Xiaofeng;Wen Zhenming;Sun Fengju;Liu Yanbo;Jiang Hongyu;Qiu Aici(State Key Laboratory of Electrical Insulation and Power Equipment,Xi’an Jiaotong University,Xi’an 710049,China;National Key Laboratory of Intense Pulsed Radiation Simulation and Effect,Northwest Institute of Nuclear Technology,Xi’an 710024,China)
机构地区:[1]西安交通大学电工材料电气绝缘全国重点实验室,西安710049 [2]西北核技术研究所,强脉冲辐射环境模拟与效应全国重点实验室,西安710024
出 处:《强激光与粒子束》2024年第11期107-114,共8页High Power Laser and Particle Beams
基 金:国家自然科学基金项目(51790523);强脉冲辐射环境模拟与效应全国重点实验室基金项目(59031905)。
摘 要:开关触发前发生的低概率自击穿故障,是制约直线变压器驱动源(LTD)技术发展和工程应用的主要因素。针对多间隙气体开关的自放电概率展开研究,设计了简化结构的气体开关来测量更高气压下的自击穿电压;推导了考虑间隙分压不均的开关自击穿电压累积分布函数,计算LTD工作气压下的多间隙开关自击穿电压分布特性并进行实验验证;通过超越阈值方法对低工作系数下的小概率自放电事件进行威布尔分布拟合,得到自放电概率估计值;对气体开关开展了万发次考核实验,得到自放电概率测量值。结果表明:开关的自击穿电压分散性随着气压升高而增加,测量低气压下的自击穿电压无法外推得到实际工作高气压条件下的自放电概率;开关工作系数为65%和60%时,气体开关的自放电概率估计值为1:44×10^(-4)和3:01×10^(-5),与开关万发次考核的实验结果相近,验证了估计方法的可行性。The pre-fire of gas switches is the unexpected breakdown at triggered mode,which is the main factor restricting the development and engineering application of linear transformer driver(LTD).In this paper,the dispersion of breakdown voltage as well as pre-fire rate of multi-gap gas switches under typical working pressures of LTD was investigated and reported.A simplified gas switch was designed to measure self-breakdown voltage at higher gas pressures,and the cumulative distribution function of self-breakdown voltage considering uneven gap voltage distribution was derived.The self-breakdown voltage distribution characteristics of multi-gap switches under LTD working pressure were calculated and experimentally verified.The estimated pre-fire rate was obtained by using peakover-threshold method to fit the Weibull distribution of small probability pre-fire events under low working coefficients.The measured pre-fire rate was obtained by a 10000 triggering test.The results show that the dispersion of the self-breakdown voltage of the switch increased with air pressure.Measuring the self-breakdown voltage at low air pressure can not extrapolate the pre-fire rate at high pressure under actual working conditions.When the working coefficients of the gas switch were 65%and 60%,the estimated pre-fire rates were 1:44×10^(-4)and 3:01×10^(-5),which were close to the experimental results of the 10000 triggering test,verifying the feasibility of the estimation method.
关 键 词:气体开关 直线变压器驱动器 自放电概率 威布尔分布
分 类 号:TM89[电气工程—高电压与绝缘技术]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.200