作 者:康熙 郭倩 付士峰 白佳慧 刘斌 孙胜博 郭威 KANG Xi;GUO Qian;FU Shifeng;BAI Jiahui;LIU Bin;SUN Shengbo;GUO Wei(Hebei Construction Engineering Quality Testing Center Co.,Ltd.,Shijiazhuang 050021,China;College of Mechanical Engineering,Shijiazhuang Tiedao University,Shijiazhuang 050043,China;Hebei Building Research Institute Co.,Ltd.,Shijiazhuang 050021,China;State Grid Hebei Electric Power Co.,Ltd.,Shijiazhuang 050000,China)
机构地区:[1]河北省建筑工程质量检测中心有限公司,石家庄050021 [2]石家庄铁道大学机械工程学院,石家庄050043 [3]河北省建筑科学研究院有限公司,石家庄050021 [4]国网河北省电力有限公司,石家庄050000
出 处:《建筑科学》2024年第10期30-39,51,共11页Building Science
基 金:重大科技成果转化专项“面向“双碳”的智慧用电与建筑节能应用场景示范”(22284504Z)。
摘 要:建筑保温与结构一体化技术在热工性能及墙体安全性方面较传统外墙技术都有所优化,其稳态传热性能是评估其节能效率的重要指标之一。本文首先通过实验测试验证模型精度,然后通过仿真模拟分析连接件、保温层厚度、地区气候差异等几种因素对墙体保温效果的影响程度,并将传热系数仿真模拟值与一维计算值进行比较,得出结论:连接件为8个/m^(2)、10个/m^(2)、12个/m^(2)时的传热系数模拟值与不考虑连接件等墙体构件影响的传热系数计算值相比,得出修正系数分别在1.35~1.55、1.45~1.8、1.5~1.85范围内;给出了各种构造在不同保温层厚度和不同地区时的修正系数;发现当保温系统厚度≥200 mm时,开凹槽对墙体整体的影响较小,修正系数为1,可以不做修正。本文结论可为超低能耗建筑工程热工设计提供参考。Compared with traditional exterior wall technology,building insulation and structure integration technology is optimized in terms of thermal performance and wall safety,and its steady-state heat transfer performance is one of the important indexes to evaluate its energy saving efficiency.This paper first verified the accuracy of the model through experimental tests,then analyzed the influence degree of several factors such as connectors,insulation layer thickness and regional climate differences on the wall insulation effect through simulation,and compared the simulated value of heat transfer coefficient with the one-dimensional calculated value,to draw a conclusion:Compared with the heat transfer coefficients calculated without considering the influence of wall components such as connectors,the simulated values of heat transfer coefficients with 8,10 and 12 connectors/m^(2)were found to be in the range of 1.35~1.55,1.45~1.8 and 1.5~1.85,respectively.The correction coefficients of various structures with different insulation thickness and in different regions were presented.It was found that when the thickness of the insulation system was≥200 mm,the impact of grooving on the whole wall was small,and the correction factor was 1,making correction unnecessary.The conclusions of this paper can provide reference for thermal design of ultra-low-energy building projects.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.7