基于热环境测试的寒冷地区中庭式教育建筑改造提升研究  

Study on the Improvement of Atrium Educational Buildings in the Cold Areas Based on Thermal Environment Tests

在线阅读下载全文

作  者:殷玉兵 方坤 赵维玲 杨慧 刘骁[3,4] 李坤明 马健 张华[5] YIN Yubing;FANG Kun;ZHAO Weiling;YANG Hui;LIU Xiao;LI Kunming;MA Jian;ZHANG Hua(China Construction Zhongyuan Architectural Design Institute Co.,Ltd.,Zhengzhou 450000,China;China Construction Seventh Engineering Division Corp.,Lid.,Zhengzhou 450000,China;State Key Laboratory of Subtropical Building and Urban Science,South China University of Technology,Guangzhou 510641,China;School of Architecture,South China University of Technology,Guangzhou 510641,China;Department of Architecture,Henan University of Technology,Zhengzhou 450001,China;Henan Key Laboratory of Grain and Oil Storage Facility&Safety,HAUT,Zhengzhou 450001,China)

机构地区:[1]中建中原建筑设计院有限公司,郑州450000 [2]中国建筑第七工程局有限公司,郑州450000 [3]华南理工大学亚热带建筑与城市科学全国重点实验室,广州510641 [4]华南理工大学建筑学院,广州510641 [5]河南工业大学建筑学院,郑州450001 [6]河南省粮油仓储建筑与安全重点实验室,郑州450001

出  处:《建筑科学》2024年第10期52-61,共10页Building Science

基  金:国家自然科学基金项目(52108011);广东省基础与应用基础研究基金(2024A1515012129,2023A1515011137);广东省哲学社会科学规划项目(GD22XGL02);亚热带建筑与城市科学全国重点实验室自主研究课题(2024ZB06);广州市科技计划项目(2024A04J9930);河南省粮油仓储建筑与安全重点实验室开放课题(2023KF07);中国建筑第七工程局有限公司资助课题(中小型公共建筑超低能耗建筑设计关键技术研究、CSCEC7b-2022-Z-25、超低能耗建筑设计关键技术研究)。

摘  要:基于热环境测试和诊断的既有建筑节能改造,可以在有限的资源下实施更有效益的改造,同时保证室内热环境水平。以寒冷地区不通风中庭式教育建筑为例,进行热环境测试,发现中庭区域在春季典型日比内走廊区域温度低1.7℃,夏季高0.6℃;长时间尺度测试显示,春季中庭区域比底层非中庭区域温度高4.5℃,夏季高3.7℃。同时,在夏季典型日7:00—10:00,设置水平遮阳的北向教室平均温度比南向房间高0.5℃。基于测试,提出通风遮阳中庭和北向垂直遮阳的综合改造设计策略,改造后中庭空气温度平均降低0.7℃,中庭建筑夏季空调能耗降低9%。最后总结得出的基于热环境测试的既有建筑更新改造设计应用流程,为同类型建筑推动更新改造提供方法和理论借鉴。Based on thermal environment tests and diagnosis,energy-saving renovation of existing buildings can be implemented more efficiently with limited resources,while ensuring the level of indoor thermal environment.This paper took an educational building with an unventilated atrium in a cold area as an example to measure and analyze the thermal environment.It was found that the temperature in the atrium area was 1.7 C lower than that in the inner corridor area on typical days in spring and o.6 C higher in summer.Long timescale tests showed that the temperature in the atrium area was 4.5℃higher than that in the non-atrium area on the ground floor in spring,and 3.7℃C higher in summer.Meanwhile,on typical summer days from 7:00 to 10:00,the average temperature of the north-facing classroom with horizontal shading was O.5℃higher than that of the south-facing classroom.Based on the tests,this paper proposed a comprehensive renovation design strategy of a ventilated and shaded atrium and north-facing vertical shading.After the renovation,the average air temperature in the atrium decreased by O.7 C,

关 键 词:中庭式建筑 热环境测试 改造设计 模拟分析 绿色建筑 绿色校园 

分 类 号:TU831[建筑科学—供热、供燃气、通风及空调工程]

 