检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:Dewang Yang Wenhua Li Lei Guo Yuhang Ji Yanzhe Gong Junwei Chu Libin Du Yongmei Wang
机构地区:[1]College of Ocean Science and Engineering,Shandong University of Science and Technology,Qingdao 266590,China [2]Xi'an Institute of Applied Optics,Xi'an 710065,China [3]College of Safety and Environmental Engineering,Shandong University of Science and Technology,Qingdao 266590,China [4]State Key Laboratory of Mining Disaster Prevention and Control Co-founded by Shandong Province and the Ministry of Science and Technology,Shandong University of Science and Technology,Qingdao 266590,China
出 处:《Chinese Journal of Chemical Engineering》2024年第9期146-153,共8页中国化学工程学报(英文版)
基 金:the National Natural Science Foundation of China(52304236);the Natural Science Foundation of Shandong Province(ZR2021QE076)for the financial support to this research extracted from the project.
摘 要:Rapid and sensitive detection of dissolved gases in seawater is quite essential for the investigation of the global carbon cycle.Large quantities of in situ optical detection techniques showed restricted measurement efficiency,owing to the single gas sensor without the identification ability of multiple gases.In this work,a novel gas-liquid Raman detection method of monitoring the multi-component dissolved gases was proposed based on a continuous gas-liquid separator under a large difference of partial pressure.The limit of detection(LOD)of the gas Raman spectrometer could arrive at about 14 μl·L^(-1)for N_(2)gas.Moreover,based on the continuous gas-liquid separation process,the detection time of the dissolved gases could be largely decreased to about 200 s compared with that of the traditional detection method(30 min).Effect of equilibrium time on gas-liquid separation process indicated that the extracted efficiency and decay time of these dissolved gases was CO_(2)>O_(2)>N_(2).In addition,the analysis of the relationship between equilibrium time and flow speed indicated that the decay time decreased with the increase of the flow speed.The validation and application of the developed system presented its great potential for studying the components and spatiotemporal distribution of dissolved gases in seawater.
关 键 词:Dissolved gas Rapid quantitative analysis Gas-liquid separator Gas-liquid Raman spectroscopy
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.179