某电潜泵油井Y型管柱堵塞器失效分析与故障处理措施  

Analysis and Treatment of Y-Type String Blocker Failure in an Electric Submersible Pump Oil Well

在线阅读下载全文

作  者:朱永刚 董宝柱 陈涛 ZHU Yonggang;DONG Baozhu;CHEN Tao(Tianjin Branch,CNOOCCo.,Ltd.,Tianjin 300459,China)

机构地区:[1]中海石油(中国)有限公司天津分公司,天津300459

出  处:《天津科技》2024年第11期40-43,共4页Tianjin Science & Technology

摘  要:某Y型电泵分采管柱油井在测静压作业结束后启泵恢复生产时,发现电泵生产工况异常,井口无液流返出。采用提出问题、进行假设、求证验证的方法,分析确认故障原因为Y型管柱堵塞器滑脱失效,针对该问题及时进行处理,使电潜泵油井恢复正常生产,从而节省了处理油井故障的费用。This paper introduces a case where,after the completion of the static pressure measurement operation for an electric submersible pump(ESP)well with a Y-type production string,when the pump was started to resume production,it was found that the production conditions of the pump were abnormal,with no fluid flow returning to the wellhead.By using the method of asking questions,making assumptions,and verifying them,it was demonstrated and analyzed that the slippage failure of the Y-type string blocker occurred.The problem was promptly addressed to restore the normal production of the electric submersible pump well,saving the cost of dealing with the oil well failure.

关 键 词:测静压 Y型电泵分采 Y堵失效 坐封Y堵 

分 类 号:TE355[石油与天然气工程—油气田开发工程]

 