基于数字孪生虚拟漏磁场波形的变压器早期故障保护研究  

Research on Transformer Incipient Fault Protection Based on Virtual Leakage Field Waveform of the Digital Twin Model

在线阅读下载全文

作  者:邓祥力 马倩 童志祥 严康 吴诗华 王振 王俊超 DENG Xiangli;MA Qian;TONG Zhixiang;YAN Kang;WU Shihua;WANG Zhen;WANG Junchao(School of Electric Power Engineering,Shanghai University of Electric Power,Yangpu District,Shanghai 200090,China;China Yangtze Power Company,Kunming 650205,Yunnan Province,China;Shanghai Urban Construction Design&Research Institute(Group)Co.,Ltd.,Pudong New Area,Shanghai 200125,China)

机构地区:[1]上海电力大学电气工程学院,上海市杨浦区200090 [2]中国长江电力股份有限公司,云南省昆明市650205 [3]上海市城市建设设计研究总院(集团)有限公司,上海市浦东新区200125

出  处:《电网技术》2024年第11期4806-4815,I0099,I0100,共12页Power System Technology

基  金:中国长江电力股份有限公司项目(Z522302029)。

摘  要:针对传统变压器差动保护无法反应内部早期故障的不足,该文提出基于非理想绕组变压器数字孪生模型的早期故障保护方案。考虑工程应用中变压器的非理想结构,利用叠加法和分离变量算法,求解绕组空间漏磁场,并建立与实际非理想变压器一致的电路-漏磁场多状态数字孪生模型。以实际变压器等效漏磁通波形与数字孪生变压器模型虚拟波形之间差异作为故障特征量,提出早期故障的保护判据,能识别出1%以下的匝间短路和轻微绕组变形。最后,利用动模试验和仿真分析验证了所提方案的正确性。Because traditional differential protection of transformers cannot reflect the incipient fault,this paper proposes an incipient fault protection scheme based on the digital twin model of a non-ideal winding transformer.Considering the non-ideal structure of transformers in engineering applications,this article uses the superposition method and separation variable algorithm to solve windings'spatial leakage magnetic field.It establishes a multi-state digital twin model consistent with the actual non-ideal transformer,which includes an electric circuit and leakage magnetic field.The proposed scheme takes the difference between the equivalent leakage flux waveform of the actual transformer and the virtual waveform of the digital twin transformer model as the fault characteristic,the protection criterion of incipient failure is proposed,and the inter-turn short circuit which is below 1%,and slight winding deformation can be identified.Finally,the correctness of the proposed scheme is verified by dynamic model tests and simulation analysis.

关 键 词:早期故障 非理想结构 叠加法 等效漏磁通 故障识别 

分 类 号:TM721[电气工程—电力系统及自动化]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象