作 者:武义锋 张海峰[1,2,3,4] 曾环 杨杨[2,3,4] Wu Yifeng;Zhang Haifeng;Zeng Huan;Yang Yang(The 16th Institute of CETC,Hefei 230043,China;Anhui Vacree Technologies Co.,Ltd,Hefei 230088,China;Anhui Provincial Key Laboratory of Rare Gas Separation Technology,Hefei 230088,China;Anhui Cryogenic and Vacuum Engineering Research Center,Hefei 230088,China)
机构地区:[1]中国电子科技集团公司第十六研究所,合肥230043 [2]安徽万瑞冷电科技有限公司,合肥230088 [3]稀有气体分离技术安徽省重点实验室,合肥230088 [4]安徽省低温与真空工程研究中心,合肥230088
出 处:《低温与超导》2024年第9期95-100,共6页Cryogenics and Superconductivity
基 金:安徽省科技重大专项(18030901038)资助。
摘 要:某型真空环境实验装置采用泵口法兰直径800 mm的低温真空泵作为解决方案,实现大抽速、无油洁净的抽空需求。该型低温真空泵采用2台GM制冷机作为制冷源,不需要低温液体辅助冷却。2台GM制冷机总计可以提供220 W@77 K、12 W@16 K的制冷量,超过了低温泵的系统热负荷,存在一定的富裕制冷量。在对该型低温泵的泵壳体、障板、吸附阵等关键部件的设计时,按照低温泵的相关理论公式进行计算求解,并综合考虑了结构强度、指标需求和工作裕度等因素,最后通过ANSYS仿真分析软件对温度场进行了模拟分析,模拟结果证实障板、吸附阵的设计满足工作要求。DN800型低温泵实测的最低温度为10.1 K,实测的降温时间195 min,实测氮气抽速为30000 L/s,实测氩气抽速为24000 L/s,实测氢气抽速为54000 L/s。DN800 cryopump with 800 mm diameter was needed by certain type of vacuum environment experimental device to realize the evacuation demand of large pumping speed and oil-free clean.It used two GM cryocoolers as the refrigeration source and did not need cryogenic liquid auxiliary cooling.The two GM cryocoolers could provide cooling capacities of 220 W@77 K and 12 W@16 K,which exceeded the system heat load of the cryopump,and there was a certain rich cooling capacity.In the design of pump shell,barrier,adsorption array and other key components of the cryopump,according to the theoretical formula of cryopump,the structural strength,index requirements and working margin,finally through the ANSYS simulation analysis software,the simulation results confirm that the design of barrier and adsorption array meet the work requirements.The final experimental results of cooling time and pumping speed confirm that DN800 cryopump can meet the requirements of technical indicators.The measured minimum temperature of DN800 cryopump is 10.1 K,the measured cooling time is 195 min,the measured speed of nitrogen is 30000 L/s,the measured speed of argon is 24000 L/s,and the measured speed of hydrogen is 54000 L/s.
分 类 号:TB752.3[一般工业技术—真空技术]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.7