摘  要:文章简要介绍了某型船电站监控系统的工作原理、典型故障及解决方法。成功解决了主开关逆功率分断后无法触发电站监控报警,1^(#)、2^(#)发电机组无法半自动并车,后电站跨接段、跨接电流不显示,前电站控制器控制面板显示器启动慢等疑难故障。The paper briefly introduces the working principle,typical faults and solutions of a certain type of ship power station monitoring system.It has successfully solved difficult faults such as the inability to trigger the power station monitoring alarm after the main switch reverse power disconnection,the inability of 1^(#) and 2^(#) gensets to semi-automatically parallelize,the non-display of the rear power station cross-connection section and cross-connection current,and the slow startup of the control panel monitor of the front power station controller.