核电厂火灾事故规程接口设计方法研究  

Study on the Interface Design Method of Fire Action Operator Sheets in Nuclear Power Plant

在线阅读下载全文

作  者:张秀春[1,2,3,4] 黄永恩 梅亮 夏虹 刘永康[6] 杨自军 张捷 刘洁 许俊俊 ZHANG Xiuchun;HUANG Yongen;MEI Liang;XIA Hong;LIU Yongkang;YANG Zijun;ZHANG Jie;LIU Jie;XU Junjun(Key Laboratory of Nuclear Safety and Advanced Nuclear Energy Technology,Ministry of Industry and Information Technology,Harbin Engineering University,Harbin of Heilongjiang Prov.150001,China;Fundamental Science on Nuclear Safety and Simulation Technology Laboratory,Harbin Engineering University,Harbin of Heilongjiang Prov.150001,China;Suzhou Nuclear Power Research Institute Co.,Ltd.,Suzhou of Jiangsu Prov.215000,China;National Engineering Research Center for Nuclear Power Plant Safety&Reliability,Suzhou of Jiangsu Prov.215000,China;Fangchenggang Nuclear Power,Fangchenggang of Guangxi Prov.538000,China;China Nuclear Power Technology Research Institute Co.,Ltd.Shenzhen of Guangdong Prov.518000,China)

机构地区:[1]哈尔滨工程大学核安全与先进核能技术工信部重点实验室,黑龙江哈尔滨150001 [2]哈尔滨工程大学核安全与仿真技术国防重点学科实验室,黑龙江哈尔滨150001 [3]苏州热工研究院有限公司,江苏苏州215000 [4]国家核电厂安全及可靠性工程技术研究中心,江苏苏州215000 [5]广西防城港核电有限公司,广西防城港538000 [6]中广核研究院有限公司,广东深圳518000

出  处:《核科学与工程》2024年第4期886-893,共8页Nuclear Science and Engineering

摘  要:针对核电厂缺少火灾事故规程(FAIOp)与其相关运行技术文件接口的系统性设计方法,使得核电厂运行阶段安全防火分区设计理念在与FAIOp相关的运行技术文件中贯彻得不彻底的问题,提出核电厂火灾事故规程接口设计方法。将该方法应用于某电厂指定区域的火灾,可顺利调用相关运行技术文件,从而保证该区域在发生被FAIOp覆盖的火灾需执行FAIOp时电厂的安全运行。本文的研究方法可推广至采用安全防火分区设计的任何堆型的核电厂。In view of the lack of a systematic design method for the interface between Fire Action Operator Sheets(FAIOp)and theirs related operation technical documents in nuclear power plant,which makes the design concept of safety and fire compartment in the operation stage of nuclear power plant not fully implemented in the operation technical documents related to FAIOp.This paper puts forward a design method for the interface of the fire accident procedures in the nuclear power plant.By applying this method to a fire in a designated area of a power plant,the relevant operation technical documents can be assessed smoothly,so as to ensure the safe operation of the power plant when the fire covered by the FAIOp needs to be carried out.The research method in this paper can be extended to any nuclear power plant with fire compartment design.

关 键 词:核电厂火灾 FAIOp DOIS EOP 

分 类 号:TL48[核科学技术—核技术及应用]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象