检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:朱炳洋 吴建锋 王柯 王章权[2] 刘半藤[2] ZHU Bingyang;WU Jianfeng;WANG Ke;WANG Zhangquan;LIU Banteng(School of Information Engineering,Huzhou University,Huzhou 313000,China;College of Information Science and Technology,Zhejiang Shuren University,Hangzhou 310015,China;State Key Laboratory of Industrial Control Technology,Zhejiang University,Hangzhou 310027,China)
机构地区:[1]湖州师范学院信息工程学院,浙江湖州313000 [2]浙江树人学院信息科技学院,浙江杭州310015 [3]浙江大学工业控制技术国家重点实验室,浙江杭州310027
出 处:《浙江大学学报(工学版)》2024年第12期2547-2555,2585,共10页Journal of Zhejiang University:Engineering Science
基 金:浙江省自然科学基金资助项目(LY20H090001,LQ23F030002);浙江省“领雁”研发攻关计划资助项目(2022C03122);浙江大学工业控制技术国家重点实验室开放课题资助项目(ICT2022B34)。
摘 要:为了减少对传统多导睡眠图(PSG)系统的依赖,基于单通道心电图(ECG)信号,设计了一种简单高效的睡眠分析算法.采用最大重叠离散小波变换(MODWT)对原始信号进行多分辨分析,再进一步提取峰值信息;根据峰值位置的一阶偏差,提取多维度的心率变异性(HRV)特征.为了进一步筛选与不同睡眠阶段具有强关联性的HRV特征,提出基于ReliefF算法与Gini指数的特征提取方法.在此基础上,采用INFO-ABCLogitBoost方法挖掘HRV与不同睡眠阶段之间的关联性,从而实现睡眠阶段的精细分类.在实际公开数据集上的实验结果表明,所提出的模型在睡眠分期任务中,总体精度为83.67%,准确率为82.59%,Kappa系数为77.94%,F1-Score为82.97%.相比于睡眠分期任务中的常规模型,所提方法展现出更加高效便捷的睡眠质量评估性能,有助于实现家庭或移动医疗场景下的睡眠监测.A simple and efficient sleep analysis algorithm was designed based on single-channel electrocardiogram(ECG)signals,in order to reduce the dependence on polysomnography(PSG)system.First,maximum overlap discrete wavelet transform(MODWT)was used to perform multi-resolution analysis on the original signal,then to furture extract peak information.Then,the multi-dimensional heart rate variability(HRV)features were extracted based on the first-order deviation of the peak position.To further screen the HRV features with a strong correlation with different sleep stages,a feature extraction method was proposed based on the ReliefF algorithm and Gini index.On this basis,the INFO-ABCLogitBoost method was used to mine the correlation between HRV and different sleep stages,thereby achieving a fine classification of sleep stages.Experimental results on actual public data sets showed that the proposed model had an overall accuracy of 83.67%,an accuracy rate of 82.59%,a Kappa coefficient of 77.94%,and an F1-Score value of 82.97%in the sleep staging task.Compared with conventional models in sleep staging tasks,the proposed method shows more efficient and convenient sleep quality assessment performance,which helps realize sleep monitoring in home or mobile medical scenarios.
关 键 词:睡眠分析 心电图(ECG) 最大重叠离散小波变换(MODWT) 心率变异性(HRV) INFO-ABCLogitBoost
分 类 号:TP391[自动化与计算机技术—计算机应用技术]