发射台站UPS蓄电池智能监测系统的构建  

Construction of Intelligent Monitoring System for UPS Battery at Launching Station

在线阅读下载全文

作  者:刘劲松 张宇 华文 Liu Jinsong;Zhang Yu;Hua Wen(Yangzhou Radio and Television Media Group,Jiangsu 225000,China)

机构地区:[1]扬州广播电视传媒集团,江苏225000

出  处:《广播与电视技术》2024年第11期88-91,共4页Radio & TV Broadcast Engineering

摘  要:UPS在广播电视信号安全播出中作为电源应急手段,重要性不断提升。蓄电池组作为UPS电源的关键部分,定期人为充放电检测性能存在较大局限性。本文构建UPS蓄电池智能监测系统,实现对每节蓄电池的实时智能监测与性能分析,能及时发现性能劣化的蓄电池,消除人工定期维护的盲区和风险,确保UPS系统良好运行,为安全播出工作提供可靠技术保障。The importance of UPS as a power emergency measure in the safe broadcast of radio and television signals is constantly increasing.The battery pack is an important part of the UPS power supply,and the regular artificial charging and discharging way to detect its performance has great limitations.This article constructs an intelligent monitoring system for UPS batteries,which realizes real-time intelligent monitoring and performance analysis of each battery of the UPS system,and can timely find the battery with deteriorated performance,thereby eliminating the blind zone and risk of manual regular maintenance,ensuring that the UPS system is running in good condition,and providing reliable technical support for safe broadcast work.

关 键 词:UPS蓄电池 智能监测 性能分析 系统构建 

分 类 号:TM912[电气工程—电力电子与电力传动]

 