检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:Penghui Ren Jingwen Zheng Liang Qin Ruyin Sun Shiqi Yang Jiangjun Ruan Kaipei Liu Tinghui Ouyang
机构地区:[1]Hubei Key Laboratory of Power Equipment&System Security for Integrated Energy,Wuhan 430072,P.R.China [2]School of Electrical Engineering and Automation,Wuhan University,Wuhan 430072,P.R.China [3]Electric Power Research Institute,State Grid Hubei Electric Power Co.,Ltd.,Wuhan 430077,P.R.China [4]Center for Computational Sciences,University of Tsukuba(UT),Ibaraki 305-8577,Japan
出 处:《Global Energy Interconnection》2024年第5期563-576,共14页全球能源互联网(英文版)
基 金:National Natural Science Foundation of China(51977160)“Voltage Self balancing Control Method for Modular Multilevel Converter Based on Switching State Matrix”.
摘 要:The application of virtual synchronous generator(VSG)control in flywheel energy storage systems(FESS)is an effective solution for addressing the challenges related to reduced inertia and inadequate power supply in microgrids.Considering the significant variations among individual units within a flywheel array and the poor frequency regulation performance under conventional control approaches,this paper proposes an adaptive VSG control strategy for a flywheel energy storage array(FESA).First,by leveraging the FESA model,a variable acceleration factor is integrated into the speed-balance control strategy to effectively achieve better state of charge(SOC)equalization across units.Furthermore,energy control with a dead zone is introduced to prevent SOC of the FESA from exceeding the limit.The dead zone parameter is designed based on the SOC warning intervals of the flywheel array to mitigate its impact on regular operation.In addition,VSG technology is applied for the grid-connected control of the FESA,and the damping characteristic of the VSG is decoupled from the primary frequency regulation through power differential feedback.This ensures optimal dynamic performance while reducing the need for frequent involvement in frequency regulation.Subsequently,a parameter design method is developed through a small-signal stability analysis.Consequently,considering the SOC of the FESA,an adaptive control strategy for the inertia damping and the P/ωdroop coefficient of the VSG control is proposed to optimize the grid support services of the FESA.Finally,the effectiveness of the proposed control methods is demonstrated through electromagnetic transient simulations using MATLAB/Simulink.
关 键 词:Flywheel array control Virtual Synchronous Generator MICROGRID Frequency regulation Adaptive control
分 类 号:TM73[电气工程—电力系统及自动化] TM341