摘 要:针对电驱动系统用高功率密度永磁驱动电机存在的不可逆退磁问题,以一款8极48槽的双V型永磁同步电机为例对退磁故障的动态识别方法进行了研究。在考虑电机闭合磁路对永磁体退磁故障影响的基础上,通过分析高退磁率电机模型退磁前后的空载和负载参数变化,采用Pearson相关性分析的方法提取了表征退磁故障的特征参量,给出了一种退磁故障的动态识别方法,并分析了转速和电流对特征参量的影响,完成了对退磁故障动态识别方法的修正。通过仿真和实验测试的方法对退磁故障动态识别方法的准确性进行了验证,结果表明,仿真结果的误差为0.68%,实验测试的预测结果最大误差为1.765%,误差均在可接受范围内。With the gradual development of permanent magnet drive motors in the direction of high speed,high torque,and high power density,the risk of irreversible demagnetization of permanent magnets has increased dramatically.In addition,rotor poles combined with multiple permanent magnets are widely used,and spatial specificity exists in pole demagnetization of space-distributed permanent magnets due to the different arrangement positions.Therefore,real-time detection of special demagnetization faults for permanent magnet drive motors is crucial.Numerous scholars have proposed online diagnostic methods.However,these methods either have the cost increase caused by the stator coil modification,or the assumed demagnetization model of the permanent magnet is far from the actual.Hence,the online diagnostic methods for the demagnetization fault have yet to be verified by experiments.In this paper,taking a permanent magnet motor with an 8-pole 48-slot double V-type as an example,the influence of the closed magnetic circuit of the motor on the demagnetization fault of permanent magnets is considered.Firstly,Assuming that the motor has good heat dissipation and ignores the axial temperature difference effect on the demagnetization of permanent magnets,the permanent magnet demagnetization caused by the armature reverse magnetic field is analyzed.Meanwhile,this paper establishes a high demagnetization rate motor model under different armature currents,considering the difference between the closed magnetic circuit inside the motor and the magnetic circuit outside the motor.Then,the motor’s no-load and load parameters are analyzed.The Person correlation coefficient method extracts the characteristic parameters of permanent magnet motor demagnetization faults.The dynamic identification method of the demagnetization fault is established,and the armature current is introduced to correct this dynamic identification method.Finally,the simulation error of the dynamic identification method is calculated by establishing a new motor model w
关 键 词:驱动电机 双V型永磁同步电机 退磁故障 Pearson相关性
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.49