机构地区:[1]The First Affiliated Hospital of Chongqing Medical University,Chongqing Branch(Municipality Division)of National Clinical Research Center for Ocular Diseases,Chongqing,China [2]Department of Orthopedics,The First Affiliated Hospital of Chongqing Medical University,Orthopaedic Research Laboratory,Chongqing Medical University,Chongqing,China [3]Key Laboratory of Clinical Laboratory Diagnostics(Ministry of Education),College of Laboratory Medicine,Chongqing Medical University,Chongqing,China [4]State Key Laboratory of Food Science and Resources,School of Food Science and Technology,Nanchang University,Nanchang,China
出 处:《Aggregate》2024年第4期308-318,共11页聚集体(英文)
基 金:National Natural Science Foundation of China,Grant/Award Numbers:82202642,82302646,32172296;Chongqing Postdoctoral Innovation Talent Support Program,Grant/Award Number:CQBX202218;China Postdoctoral Science Foundation,Grant/Award Numbers:2022M710558,2023T160771;Special foundation of Chongqing Postdoctoral Research Programme,Grant/Award Number:2021XM2036;Talent Training Foundation of Key Laboratory of Clinical Laboratory Diagnostics(Ministry of Education)of College of Laboratory Medicine,Grant/Award Number:JYPY202202;Chongqing Postdoctoral Science Foundation,Grant/Award Number:CSTB2022NSCQ-BHX0689;National Natural Science Foundation Key Program,Grant/Award Numbers:82230032,81930023;Key Project of Chongqing Science and Technology Bureau,Grant/Award Number:CSTC2021jscx-gksb-N0010;Chongqing Outstanding Scientists Project(2019);Chongqing Chief Medical Scientist Project(2018);Chongqing Science and Technology Bureau Mountaineering Project,Grant/Award Numbers:cyyy-xkdfjh-jcyj-202301,cyyy-xkdfjh-lcyj-202303,cyyy-xkdfjh-cgzh-202302。
摘 要:Accurate and sensitive near-infrared(NIR)luminescent lateralflow immunoassay(LFIA)has attracted considerable attention in thefield of point-of-care testing(POCT).However,the detection accuracy and sensitivity are often compromised by the lowfluorescence quantum efficiency of the NIRfluorescent probe.(<10%)Herein,ultrabright NIR AIEgen nanoparticles(PS@AIE830NPs)composed of polystyrene(PS)nanoparticles and NIR aggregation-induced emission luminogen(AIEgen)with the maximum emission at 830 nm(AIE830)is reported,and its poten-tial to promote an accurate and sensitive detection of complex samples by LFIA is described.The relative quantum yield(QY)of the PS@AIE830NPs was 14.76%,which was superior to that of the polymer embedding method and indocyanine green(ICG)-based NIR nanoparticles.The PS@AIE830NPs immunolabeled-LFIA com-bined with laboratory-built NIR-LFIA portable quantitative instruments(detected light range 800 nm)completely eliminated background interference and allowed>highly accurate and sensitive detection without any pre-treatment steps.The limits of detection(LODs)for aflatoxin B1(AFB1)in soy sauce,alpha hemolysin(Hla)of Staphylococcus aureus biomarker in jointfluid,and C-reactive protein(CRP)in human haemolysed samples were 0.01 ng mL^(-1),0.02µg mL^(-1),and 0.156 mg L^(-1),respectively,commensurating with those of the corresponding gold standard assays and covering the detection range of interests.It is anticipated that the ultrabright NIR AIEgen nanoparticles will serve as a universally applicable signal probe for NIR-LFIA diagnostics,promising to expand the range of applications for quantitative detection of complex samples.
关 键 词:aggregation-induced emission complex sample lateralflow immunoassay NEAR-INFRARED rapid diagnostic testing
分 类 号:TB383[一般工业技术—材料科学与工程]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...