检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:杨亚宇 邰能灵[2,3] 黄文焘[2] 余墨多 刘宇 Yang Yayu;Tai Nengling;Huang Wentao;Yu Moduo;Liu Yu(Logistics Engineering College Shanghai Maritime University,Shanghai 201306 China;Key Laboratory of Control of Power Transmission and Conversion Ministry of Education Shanghai Jiao Tong University,Shanghai 200240 China;College of Smart Energy Shanghai Jiao Tong University,Shanghai 200240 China;School of Information Science and Technology ShanghaiTech University,Shanghai 201210 China)
机构地区:[1]上海海事大学物流工程学院,上海201306 [2]上海交通大学电力传输与功率变换控制教育部重点实验室,上海200240 [3]上海交通大学国家电投智慧能源创新学院,上海200240 [4]上海科技大学信息科学与技术学院,上海201210
出 处:《电工技术学报》2024年第23期7341-7364,共24页Transactions of China Electrotechnical Society
基 金:国家自然科学基金(52337006);上海市2023年科技创新行动计划启明星培育(扬帆计划)(23YF1416000);上海市优秀学术带头人计划(22XD1401400);电力传输与功率变换控制教育部重点实验室开放课题(2022AB02);上海市科技计划(20040501200)资助项目。
摘 要:船舶中压直流综合电力系统代表船舶综合电力系统的发展方向,是我国实施海洋强国战略的重要基础。作为论文的第二部分,该文聚焦船舶中压直流综合电力系统故障保护管理技术。船舶中压直流综合电力系统故障保护管理技术包括故障特性分析、继电保护原理、故障隔离方案和故障后重构方法四部分。首先,分析了其特殊技术要求;其次,归纳总结了船舶中压直流综合电力系统的故障特性、继电保护算法的现有技术及其存在的问题,阐述了船舶中压直流综合电力系统的故障隔离方案、故障后重构方法的研究现状,并进行了详细对比和分析;最后,对船舶中压直流综合电力系统故障保护管理技术进行了总结和展望。The shipboard medium-voltage DC(MVDC)integrated power system(IPS)is the technological development direction of the shipboard IPS.As the second part,this paper focuses on the protection and fault management technology of the shipboard MVDC IPS,which includes four parts:fault characteristics analysis,protection principle,fault isolation scheme and reconfiguration method.First of all,the special technical requirements for the protection and fault management technology are analyzed.The shipboard MVDC IPS has high requirements for selectivity and speed.The protection and fault management scheme needs to fully consider the shipboard multiple operating modes and the transient response of multi-type power electronic converters.Then,the fault characteristics analysis method and the protection principle are summarized,and the limitations are outlined.Subsequently,the fault isolation scheme and reconfiguration method are comprehensive reviewed,and the detailed comparisons are made respectively.Finally,the future research trends of the protection and fault management technology of the shipboard MVDC IPS are pointed out.1)Fault characteristics analysis.The fault transient characteristics analysis methods based on time-frequency domain transformation,nodal impedance matrix analysis,topology simplification,and pole-mode transformation analysis in multi-terminal DC(MTDC)transmission and distribution system provide important references for the shipboard MVDC IPS.However,the fault characteristic analysis model of the complex topology shipboard MVDC IPS containing multi-type power electronic converters,multiple system nodes and multiple operating modes still needs to be studied.2)Protection principle.Intelligent protection methods require a large amount of training data,which limits the engineering applications.The shipboard MVDC IPS protection can draw on the existing MTDC transmission and distribution system protection method to a certain extent.However,due to the short ship cables,inconsistent DC line boundaries,multiple system
关 键 词:中压直流 船舶综合电力系统 故障特性分析 继电保护 故障隔离
分 类 号:TM771[电气工程—电力系统及自动化]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.7