摘 要:分析目前净水厂电气设计、施工及运营管理中存在的若干问题,从负荷特点分析及负荷计算、供电电源、变电所设置及变压器选择、高低压变配电系统、电机拖动、谐波治理、电气节能等方面进行讨论,给出各问题的解决方案,并在优化净水厂电气设计以及完善水厂功能方面给出了建议。Several issues in electrical system design for water purification plants,emerged during design,construction and operation management,are analyzed in this paper.And then,the solutions to the above-mentioned problems lie in load analysis and load calculation,power supply,electrical substation and transformer selection,high-voltage and low-voltage power distribution,motor drives,harmonic suppression,energy conservation measures are given.Furthermore,we present some suggestions for power supply and distribution system design optimization of water purification plants,and for their function extension.
关 键 词:净水厂 供配电 负荷计算 供电电源 电机拖动 谐波治理 电气节能