Gamma ray and neutron shielding capacity of and dosimetry of composite compounds with diagnostic and therapeutic energies  

在线阅读下载全文

作  者:H.Hosseini Sarteshnizi M.Eshghi 

机构地区:[1]Department of Physics,Imam Hossein Comprehensive University,Tehran,Iran

出  处:《Radiation Detection Technology and Methods》2024年第2期1217-1228,共12页辐射探测技术与方法(英文)

摘  要:Purpose Ionizing radiation protection is one of the most fundamental research and application fields in reducing the absorbed dose of sensitive internal organs.The presence of lead as the first radiation shield with a series of good features,such as high density and having some flexibility,and a series of features such as toxicity,low physical and chemical stability and high weight has been thinking about replacing it for a long time.Therefore,in this research,we have investigated features of the ionizing radiation shielding of composite compounds without lead in the photon energy range of 15 keV to 15 MeV.Methods To extract such features,it is necessary to use a computational method.In this research,we have done all our calculations based on the Geant4 tool based on the Monte Carlo method.This tool is a multi-purpose tool that can be used for particle transport calculations such as electrons,protons,neutrons,heavy charged particles and photons in different environments such as human tissues.Results We have calculated mass attenuation coefficient(MAC)by using the Monte Carlo simulations such as Geant4 tool,XMuDat and XCOM codes.In the continuation of the investigation of the protection feature,four laboratory energies have been selected and investigated.In fact,the performance of shields against 60 keV,662 keV and 1.2 MeV sources has been investigated.In this case,we have obtained the passing flux of photons,half-value layer(HVL),tenth-value layer(TVL)and mean free path(MFP).Then,the image of the passing photon flux of ^(241)Am(60 keV),^(137)Cs(662 keV)and^(60)Co(1.2 MeV)sources for a shielding sample is showed.Since the aim is to examine the overall protection characteristics of the samples,we have considered the source as a neutron-gamma mixture and made of 252Cf.In this case,the passing fux of photons and the ratio of neutrons passing through the shields are shown.In the continuation of the work,MIRD phantom has been used to check the performance of the shields in the amount of dose reached to the body and org

关 键 词:SHIELDING Medical shielding GEANT4 Gamma ray Radiation DOSIMETRY 

分 类 号:O57[理学—粒子物理与原子核物理]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象