作 者:马士杰 吴洪波[1,3] 赵尚男 吴庆 张新[1,3] MA Shi-jie;WU Hong-bo;ZHAO Shang-nan;WU Qing;ZHANG Xin(Changchun Institute of Optics,Fine Mechanics and Physics,Chinese Academy of Sciences,Changchun 130033,China;University of Chinese Academy of Sciences,Beijing 100049,China;Key Laboratory of Advanced Manufacturing of Optical Systems,Changchun 130033,China)
机构地区:[1]中国科学院长春光学精密机械与物理研究所,吉林长春130033 [2]中国科学院大学,北京100049 [3]光学系统先进制造全国重点实验室,吉林长春130033
出 处:《中国光学(中英文)》2024年第6期1408-1417,共10页Chinese Optics
基 金:中国科学院长春光学精密机械与物理研究所青年科学基金项目(No.62005271)。
摘 要:变形光学系统是一种具有双平面对称性的相对特殊的光学系统,其结构会引入非旋转对称的偏振像差。针对这一问题,本文构建一个折反式变形光学系统,并对该系统的偏振像差及其对点扩散函数的影响进行系统分析。基于三维偏振光线追迹对折反式变形光学系统进行仿真计算,获得偏振像差的详细数据,并计算各个表面的二向衰减、相位延迟分布特性以及系统的琼斯瞳、振幅响应矩阵、点扩散函数和偏振串扰对比度。结果表明:最大二向衰减为0.145,最大相位延迟为1.46×10^(-2)rad,均出现在次镜位置。2∶1变形比的光学系统的振幅响应函数在长焦端和短焦端方向的偏振串扰项存在40.6%的差异,偏振串扰将该变形光学系统的对比度限制在10^(-6)量级。高精度变形光学系统中的偏振像差不可忽略,可采用膜层设计和折反式结构等方法降低偏振像差影响。该研究结论可为变形光学系统在深空探测、相干通信系统等领域的设计提供参考。The anamorphic optical system is a relatively special optical system with bi-planar symmetry,whose structure gives rise to non-rotationally symmetric polarization aberrations.Aiming at the problem,we construct a catadioptric anamorphic optical system.Furthermore,we also systematically analyzes the polarization aberration of this system and its effect on the point spread function.Simulations of a catadioptric anamorphic optical system based on a three-dimensional polarized light trace are performed to obtain detailed data on the polarization aberration and to compute the diattenuation and retardance distribution characteristics of individual surfaces,as well as the Jones pupil,the amplitude response matrix,the point spread function,and the polarization crosstalk contrast of the system.The maximum diattenuation is 0.145,and the maximum retardance is 1.46×10^(−2)rad,both occurring at the secondary mirror position.The amplitude response function of the optical system with a 2∶1 anamorphic ratio has a 40.6%difference between the polarization crosstalk term in the long and short focal end directions,and the anamorphic optical systems contrast is limited by an order of magnitude of 10^(−6)by polarization crosstalk.Polarization aberration in high-precision anamorphic optical systems is not negligible.The effects of polarization aberration can be reduced by film layer design and catadioptric structure.The conclusions of this study can serve as a reference for designing anamorphic optical systems in deep space exploration and coherent communication systems.
分 类 号:TP394.1[自动化与计算机技术—计算机应用技术] TH691.9[自动化与计算机技术—计算机科学与技术]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.49