Novel heart valve leaflet designs with stiff polymeric materials and biomimetic kinematics  

在线阅读下载全文

作  者:Caroline C.Smid Georgios A.Pappas Nikola Cesarovic Volkmar Falk Paolo Ermanni 

机构地区:[1]Laboratory of Composite Materials and Adaptive Structures,ETH Zürich,Leonhardstrasse 21,8092 Zürich,Switzerland [2]Translational Cardiovascular Technologies,ETH Zürich,Leopold-Ruzicka-Weg 4,8093 Zürich,Switzerland [3]Department for Cardiothoracic and Vascular Surgery,Deutsches Herzzentrum der Charité,CharitéUniversitätsmedizin Berlin,Augustenburger Pl.1,13353 Berlin,Germany [4]German Center for Cardiovascular Research(DZHK),Partner Site Berlin,Augustenburger Pl.1,13353 Berlin,Germany

出  处:《Bio-Design and Manufacturing》2024年第6期1018-1034,共17页生物设计与制造(英文)

基  金:provided by Board of the Swiss Federal Institutes of Technology;Universitat Zürich;the Laboratory of Composite Materials and Adaptive structures。

摘  要:Despite continuous efforts to improve the robustness of cardiac valve implants,neither bioprosthetic nor mechanical valves fulfill both hemodynamic and durability requirements.This study discussed novel flexible leaflet designs,focusing on polymeric materials with proven hemocompatibility,such as polyether ether ketone,of much higher stiffness than native tissue,aiming at optimal valve implants.A biomimetic valve with a single-curvature belly-curve(B-C)was used as a reference for new design variants with a double-curvature B-C with varying radii.Soft(13.2 MPa)and stiff(2.4 GPa)leaflet materials and different thicknesses were studied using lean simulations and in vitro experiments under physiologic hemodynamic conditions.The performance was assessed using opening pressure(OP)and orifice area(OA).The latter was determined by a newly developed automatized image processing tool.Experimental trends are in agreement with simulations and demonstrated that a buckling-inspired double-curvature leaflet design significantly enhances the trileaflet valve opening behavior,which is particularly advantageous for stiffer leaflet materials.Compared to the reference,the best-performing variant showed an OP improvement of 47%and 44%based on simulations and experiments,respectively.In contrast,the achieved mean pressure differential was directly comparable to state-of-the-art bioprosthetic valves.The OA was slightly reduced for new variants but still in the satisfying range.

关 键 词:Fully polymeric heart valve Parametric leaflet design Finite element analysis Leaflet kinematics In vitro testing 

分 类 号:R318.08[医药卫生—生物医学工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象