Seismic performance of damaged frame retrofitted with self-centering and energy-dissipating rocking wall  被引量:1

在线阅读下载全文

作  者:Genqi Xiao Haishen Wang Peng Pan 

机构地区:[1]Department of Civil Engineering,Tsinghua University,Beijing 100084,China [2]Key Laboratory of Civil Engineering Safety and Durability of the China Education Ministry,Tsinghua University,Beijing 100084,China

出  处:《Resilient Cities and Structures》2023年第1期143-151,共9页韧性城市与结构(英文)

基  金:support received from National Key R&D Program of China(2019YFC1509304);Natural Science Foundation of China Grant No.52121005 and Natural Science Foundation of China Grant No.52108459.

摘  要:This paper proposes the novel concept of retrofitting damaged reinforced concrete frame with self-centering and energy-dissipating rocking wall.Parametric studies were carried out base on pushover and time-history analysis.In both pushover and time-history analysis,the soft-story mechanism was effectively mitigated through the rocking wall retrofit of the damaged structures.The results demonstrated that the stiffness and bearing capacity of the retrofitted system were improved compare to its intact state.Additionally,the seismic response of the damaged frame retrofitted using rocking wall in combination with post-tension and shear-type damper fell within the relevant design limits.Pushover analysis of the rocking wall indicated that there is a linear relationship between the wall thickness and the initial stiffness of the retrofitted system.The addition of post-tension tendon to the rocking wall system enables the wall to self-center and increases lateral stiffness and bearing capacity of the retrofitted system.When the shear-type damper was installed,the energy dissipation of the system was increased,and the stiffness and bearing capacity of the retrofitted system were also improved.In the time-history analysis,it was found that the thickness of the rocking wall is directly related to the maximum inter-story drift and the distribution patterns of inter-story drift of the frame.As the post-tension was added to the system,the maximum inter-story drift under rare earthquake excitation improved significantly.With the addition of shear-type dampers,the overall drift magnitude of the retrofitted system was fundamentally decreased.

关 键 词:Rocking wall Damaged frame retrofit POST-TENSIONING Shear-type damper 

分 类 号:P31[天文地球—固体地球物理学]

 