检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:郑宇[1] Zheng Yu(China Southwest Architectural Design and Research Institute Co.,Ltd,Chengdu 610042,China)
机构地区:[1]中国建筑西南设计研究院有限公司,成都610041
出 处:《智能建筑电气技术》2024年第6期44-50,共7页Electrical Technology of Intelligent Buildings
摘 要:按GB 31247—2014燃烧性能选择电缆,对电缆的腐蚀性、烟密度、产烟毒性、燃烧滴落物/微粒、阻燃性及燃烧性能方面提出新要求。本文基于GB 51348—2019及现行类型建筑电气设计规范对电缆特性规定的层面,对比分析其异同,归纳和总结出适用于民用建筑的阻燃电缆特性指标,供行业电气设计师参考。With the implementation of Standard for electrical design of civil buildings(GB 31247-2014-2019),New requirements are put forward in terms of cable corrosion,somke density,smoke toxicity,flaming droplet/particle,flame retardance,burning behavior.This paper is based on the level of cable characteristics specified in GB 51348-2019 and current electrical design codes for types of buildings,The similarities and differences are compared and analyzed.The characteristic indexes of flame retardant cables suitable for civil buildings are summarized for the reference of electrical designers.
分 类 号:TU201[建筑科学—建筑设计及理论]