检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:Patrick W O'Regan Antonia Harold-Barry Alexander T O'Mahony Claire Crowley Stella Joyce Niamh Moore Owen J O'Connor Michael T Henry David J Ryan Michael M Maher
机构地区:[1]Department of Radiology,School of Medicine,University College Cork,Cork T12 AK54,Ireland [2]Department of Radiology,Cork University Hospital,Cork T12 DC4A,Ireland [3]Department of Radiology,Mercy University Hospital,Cork T12WE28,Ireland [4]Department of Respiratory Medicine,Cork University Hospital,Cork T12 DC4A,Ireland
出 处:《World Journal of Radiology》2024年第11期668-677,共10页世界放射学杂志(英文)
摘 要:BACKGROUND Incidental pulmonary nodules are an increasingly common finding on computed tomography(CT)scans of the thorax due to the exponential rise in CT examin-ations in everyday practice.The majority of incidental pulmonary nodules are benign and correctly identifying the small number of malignant nodules is cha-llenging.Ultra-low-dose CT(ULDCT)has been shown to be effective in diagnosis of respiratory pathology in comparison with traditional standard dose techniques.Our hypothesis was that ULDCT chest combined with model-based iterative reconstruction(MBIR)is comparable to standard dose CT(SDCT)chest in the analysis of pulmonary nodules with significant reduction in radiation dose.AIM To prospectively compare ULDCT chest combined with MBIR with SDCT chest in the analysis of solid pulmonary nodules.METHODS A prospective cohort study was conducted on adult patients(n=30)attending a respiratory medicine outpatient clinic in a tertiary referral university hospital for surveillance of previously detected indeterminate pulmonary nodules on SDCT chest.This study involved the acquisition of a reference SDCT chest followed immediately by an ULDCT chest.Nodule identification,nodule characterisation,nodule measurement,objective and subjective image quality and radiation dose were compared between ULDCT with MBIR and SDCT chest.RESULTS One hundred solid nodules were detected on ULDCT chest and 98 on SDCT chest.There was no significant difference in the characteristics of correctly identified nodules when comparing SDCT chest to ULDCT chest protocols.Signal-to-noise ratio was significantly increased in the ULDCT chest in all areas except in the paraspinal muscle at the maximum cardiac diameter level(P<0.001).The mean subjective image quality score for overall diagnostic acceptability was 8.9/10.The mean dose length product,computed tomography volume dose index and effective dose for the ULDCT chest protocol were 5.592 mGy.cm,0.16 mGy and 0.08 mSv respectively.These were significantly less than the SDCT chest protocol(P<0.
关 键 词:Ultra-low dose computed tomography Solid pulmonary nodules Computed tomography methods Radiation dosage Adult human
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.170