仓库ESRF喷头的选用——以某物流园仓库为例  

The Selection of Early Suppression Fast Response Nozzles in Warehouses:Taking a Logistics Park Warehouse as an Example

在线阅读下载全文

作  者:傅芬兰 Fu Fenlan(Fujian Mechanical and Electrical Coastal Architectural Design and Research Institute Co.,Ltd.,Fuzhou 350000)

机构地区:[1]福建省机电沿海建筑设计研究院有限公司,福州350000

出  处:《绿色建造与智能建筑》2024年第12期166-169,共4页Green Construction and Intelligent Building

摘  要:根据《自动喷水灭火系统设计规范》(GB50084-2017)中仓库采用ESRF喷头时的湿式系统设计参数和喷头的要求,进行水力计算得出设计流量与压力,通过对比分析,找出适合物流园仓库要求的自动喷淋形式。对工程设计中仓库所采用的自动喷水系统设计流量、加压泵流量和消防储水量的确定给出相应的取值,供同类别工程参考。According to the"Design Specification forAutomatic Sprinkler Fire Extinguishing Systems"(GB50084-2017),the wet system design parameters and nozzle requirements for Early Suppression Fast Response nozzles are used in warehouses.Hydraulic calculations are conducted to determine the design flow rate and pressure.Through comparison and analysis,the suitable automatic sprinkler form for logistics park warehouses is identified.Provide corresponding values for the design flow rate of the automatic sprinkler system,the selection flow rate of the pressurized pump,and the determination of the fire water storage capacity used in the warehouse in engineering design,for reference in projects of the same category.

关 键 词:仓库 早期抑制快速响应喷头 设计流量 工作压力 