检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:文波[1,2] 王怀正 汪雪峰 张海燕 王茂宇[1] WEN Bo;WANG Huaizheng;WANG Xuefeng;ZHANG Haiyan;WANG Maoyu(College of Civil Engineering,Xi’an University of Architecture and Technology,Xi’an 710055,China;Key Lab of Structural Engineering and Earthquake Resistance of the Ministry of Education,Xi’an University ofArchitecture and Technology,Xi’an 710055,China;State Key Laboratory of Green Building in Western China,Xi’an University of Architecture and Technology,Xi’an 710055,China;School of Civil Engineering and Transportation,South China University of Technology,Guangzhou 510640,China)
机构地区:[1]西安建筑科技大学土木工程学院,陕西西安710055 [2]西安建筑科技大学结构工程与抗震教育部重点实验室,陕西西安710055 [3]西安建筑科技大学西部绿色建筑国家重点实验室,陕西西安710055 [4]华南理工大学土木与交通学院,广东广州510640
出 处:《建筑结构学报》2024年第12期125-136,共12页Journal of Building Structures
基 金:国家自然科学基金项目(52378535);陕西省重点研发计划(2022KW-36);陕西省教育厅协同创新中心项目(20JY034)。
摘 要:为了提高废弃玻璃的利用率,拓展其在建筑领域的应用,将废弃玻璃研磨成粉代替石英砂制备蒸压加气混凝土砌块,进而开展了废玻璃蒸压加气混凝土砌体墙的抗震性能试验研究和有限元分析。对4片废玻璃蒸压加气混凝土砌体墙进行了3因素(高宽比、竖向压应力、砂浆强度)的正交拟静力试验,试验结果表明:废玻璃蒸压加气混凝土砌体墙的破坏模式为剪切破坏;添加玻璃粉可以显著提高墙体延性,废玻璃蒸压加气混凝土砌体墙的位移延性系数在4.74~6.00之间,墙体的抗震性能良好。通过数值模拟分析发现,适当增加竖向应力、减小高宽比、提高砂浆强度均能够提升墙体受剪性能,其中高宽比的影响程度最大。In this paper,to improve the utilization rate of waste glass and expand its application in the field of construction,waste glass was ground into powder to replace quartz sand in the preparation of autoclaved aerated concrete blocks.Experimental research and finite element analysis were conducted on the seismic performance of waste glass autoclaved aerated concrete masonry walls.An orthogonal quasi-static test was designed for four walls made of waste glass autoclaved aerated concrete masonry,considering three factors:height-width ratio,vertical compressive stress,and mortar strength.It is shown from the tests that the failure mode of waste glass autoclaved aerated concrete masonry walls is shear failure.The ductility is significantly improved by the addition of glass powder,with the ductility coefficient of waste glass autoclaved aerated concrete masonry walls ranging from 4.74 to 6.00,demonstrating good seismic performance.It is shown from the numerical simulation that the shear resistance of the walls can be improved by increasing vertical stress,reducing the height-width ratio,and improving mortar strength.Among these factors,the height-width ratio is found to have the greatest influence.
关 键 词:废玻璃蒸压加气混凝土砌体墙 拟静力试验 数值模拟 破坏模式 抗震性能
正在载入数据...