瓶装药品动态检重系统设计  

Design of Dynamic Check-weighting System for Bottled Medicine

在线阅读下载全文

作  者:赵岩[1] 吴昕 安君 宋纹 ZHAO Yan;WU Xin;AN Jun;SONG Wen(School of Electrical Engineering and Automation,Tianjin University of Technology,Tianjin 300384,China;Tianjin Hongrentang Pharmaceutical Co.,Ltd.,Tianjin 300385,China)

机构地区:[1]天津理工大学电气工程与自动化学院,天津300384 [2]天津宏仁堂药业有限公司,天津300385

出  处:《自动化与仪表》2024年第12期70-74,87,共6页Automation & Instrumentation

摘  要:针对药品生产过程中重量检测不准确、效率低的问题,为实现对瓶装药品重量的实时监测与管理,设计了一种瓶装药品动态检重系统。系统总体框架包括3个模块:检重剔除模块通过称重传感器采集重量信号,并通过称重仪表处理成重量值;人机交互模块通过触摸屏界面监控检重数据,设置检重参数;执行控制模块通过PLC实现对系统中所有电机的启停、速度控制。该系统经运行测试,表明系统在0.6 m/s~1.2 m/s速度范围内,系统始终表现出较高的检重准确度和较低的误差,系统检测精度为±0.2 g,最大平均绝对误差为0.162 g,最大平均相对误差为1.16%。Aiming at the problem of inaccurate and low efficiency of weight detection in the process of medicine production,a dynamic check-weighing system for bottled medicine is designed in order to realise real-time monitoring and management of the weight of bottled medicine.The overall framework of the system includes three modules,the check-weighing rejection module collects the weight signal through the load cell and processes it into the weight value through the weighing instrument,the human-computer interaction module monitors the check-weighing data and sets the check-weighing parameters through the touch screen interface,and the executive control module realises the start-stop and speed control of all the motors in the system through the PLC.The system has been tested in operation,showing that the system always exhibits high check-weighing accuracy and low error within the speed range of 0.6 m/s~1.2 m/s.The detection accuracy of the system is±0.2 g,with a maximum average absolute error of 0.162 g and a maximum average relative error of 1.16%.

关 键 词:动态检重 瓶装药品 称重传感器 触摸屏 PLC 

分 类 号:TP273[自动化与计算机技术—检测技术与自动化装置]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象