660MW超超临界机组发电机轴端密封漏油的原因分析与处理  

Analysis and Treatment of Oil Leakage at the Shaft End Seal of 660 MW Ultra Supercritical Unit Generator

在线阅读下载全文

作  者:刘家东 LIU Jiadong(Zhejiang Zheneng Zhenhai Power Generation Co.,Ltd.,Ningbo 315200)

机构地区:[1]浙江浙能镇海发电有限责任公司,宁波315200

出  处:《现代制造技术与装备》2024年第12期179-182,共4页Modern Manufacturing Technology and Equipment

摘  要:以某电厂超超临界发电机组的水氢氢冷发电机为研究对象。机组运行约2个月后发现发电机主出线盒检漏仪有油漏出,解体检查后发现密封瓦内油挡与轴径间隙过大,密封瓦尺寸超差是漏油的主要原因。通过调整密封支座内油挡间隙及更换新密封瓦,彻底解决了发电机组膛内漏油状况。问题的分析与处理可为该类故障处理提供参考。This thesis focuses on the water-hydrogen-hydrogen cooled generator of an ultra-supercritical generating unit in a power plant.After about 2 months of operation,oil was detected in the leak detector of the generator's main outlet box.Upon disassembly and inspection,it was found that the excessive clearance between the inner oil baffle of the seal ring and the shaft diameter,as well as the dimensional deviation of the seal ring,were the main causes of the oil leakage.By adjusting the clearance of the inner oil baffle in the seal support and replacing the seal ring with a new one,the problem of oil leakage within the generator casing was completely resolved.The analysis and treatment of this issue can provide a reference for handling similar faults.

关 键 词:660MW机组 发电机轴密封 密封瓦 解体检修 超超临界 

分 类 号:TM621[电气工程—电力系统及自动化]

 