作 者:陈碧波 龚翠丽 梁樟 CHEN Bi-bo;GONG Cui-li;LIANG Zhang(Department of Laboratory,Dongguan Renkang Hospital,Guangdong Dongguan 523952)
出 处:《中国医疗器械信息》2024年第24期53-55,共3页China Medical Device Information
摘 要:目的:分析日立7600全自动生化分析仪对脂肪肝的诊断作用。方法:将2023年1月~2023年6月本院收治的脂肪肝患者146例作为观察对象,另将同一时期接收的健康志愿者145例作为对照观察,通过日立7600全自动生化分析仪对患者的ADA、MAO、血脂等进行检验,分析两组研究对象日立7600全自动生化分析仪检验中的ADA、MAO、血脂[高密度脂蛋白(HDL-C)、低密度脂蛋白(LDL-C)、总胆固醇(TC)、天门冬酸氨基转移酶(AST)]水平变化,同时分析脂肪肝患者得到有效救治后与治疗前日立7600全自动生化分析仪检测的各项指标水平改变。结果:脂肪肝组患者ADA、MAO、血脂水平明显高于健康志愿者,对比差异有统计学意义(P<0.05);脂肪肝组患者得到有效救治后,其ADA、MAO、血脂水平低于治疗前,对比差异有统计学意义(P<0.05);治疗后脂肪肝组与健康志愿者ADA、MAO、血脂水平比较可见,差异无统计学意义(P>0.05)。结论:日立7600全自动生化分析仪在脂肪肝的诊断中具有较高的应用价值,能够通过ADA、MAO、血脂等水平的检验值辅助临床确诊脂肪肝疾病,同时还能通过全自动生化分析仪了解治疗效果。Objective:To analyze the diagnostic role of the Hitachi 7600 fully automatic biochemical analyzer in fatty liver disease.Methods:From January 2023 to June 2023,146 patients with fatty liver admitted to our hospital were selected as the study group,and 145 healthy volunteers from the same period were selected as the control group.The Hitachi 7600 fully automatic biochemical analyzer was used to test the ADA,MAO,and blood lipid levels of the patients,and to analyze the changes in ADA,MAO,and blood lipid levels(including high-density lipoprotein cholesterol(HDL-C),low-density lipoprotein cholesterol(LDL-C),total cholesterol(TC),and aspartate aminotransferase(AST))in both groups tested by the Hitachi 7600 fully automatic biochemical analyzer.Additionally,the changes in various indicators detected by the Hitachi 7600 fully automatic biochemical analyzer before and after effective treatment in patients with fatty liver were analyzed.Results:ADA,MAO,and lipid levels of patients with fatty liver group were significantly higher than those of healthy volunteers,and the comparative difference was statistically significant(P<0.05);After patients received effective treatment,their ADA,MAO,and lipid levels were lower than those before treatment,and the comparative difference was statistically significant(P<0.05);Compared with ADA,MAO,and lipid levels,the difference was not statistically significant(P>0.05).Conclusion:Hitachi 7600 automatic biochemical analyzer has a high application value in the diagnosis of fatty liver.It can assist the clinical diagnosis of fatty liver disease through the test value of ADA,MAO and blood lipid levels.At the same time,it can also understand the treatment effect through the automatic biochemical analyzer.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:18.221.242.128