出 处:《CSEE Journal of Power and Energy Systems》2024年第6期2587-2596,共10页中国电机工程学会电力与能源系统学报(英文)
基 金:supported in part by the National Key Research and Development Program of China(Basic Research Class 2017YFB0903000);the National Natural Science Foundation of China(51677116);the Science and Technology Project of State Grid Corporation of China:Basic Theory and Method of Analysis and Control of Cyber Physical System for Power Grid(Supporting Project).
摘 要:With the access to large amounts of renewable energy sources(RES),operation uncertainty of distribution networks increases significantly.Fortunately,adopting advanced information and communication technology,a cyber-physical distribution network(CPDS)provides the possibility to solve this problem via aggregative management of decentralized controllable loads.However,information flow in cyber space deeply interacts with energy flow in physical space,leading to a complexity in modeling,design and analysis of the whole control process.To deal with this problem,a general hybrid flow model of CPDS is first proposed in this paper.In this model,the control process is abstracted into interactions among three types of cyber nodes through cyber branches.The mathematic model of cyber nodes and branches is developed as well as that of the controlled physical object for hybrid flow computation.Then,based on the hybrid model,an instantiated application to compensate feeder power deviation caused by RES fluctuation through aggregative control of large-scale air-conditioners(ACs)is investigated.In this application,coordinative control of the AC cluster is achieved through a decentralized control strategy with very little communication cost and very good privacy protection.Results of numerical examples verify the correctness and flexibility of the hybrid flow model in reflecting interactions between cyber flow and energy flow as well as system operations.The proposed decentralized control strategy of the AC cluster is also proven to be effective and robust in FCE compensation.
关 键 词:Air-conditioner load cyber physical distribution network decentralized control feeder control error hybrid flow model mixed logical dynamic renewable energy source
分 类 号:TM727[电气工程—电力系统及自动化]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.219