检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:付刚 李仁斌 陶鑫钰 李桂林 葛晖 陈建龙 林绪超 陈培生 林凤飞 Fu Gang;Li Renbin;Tao Xinyu;Li Guilin;Ge Hui;Chen Jianlong;Lin Xuchao;Chen Peisheng;Lin Fengfei(Department of Orthopaedics,The Second General Hospital of Fuzhou,Teaching Hospital of Fujian Medical University,Department of Clinical Medicine,Fujian Medical University,Fuzhou 350007,China)
机构地区:[1]福州市第二总医院创伤骨科,福建医科大学教学医院,福建医科大学临床医学部,福州350007
出 处:《中华创伤骨科杂志》2024年第11期991-996,共6页Chinese Journal of Orthopaedic Trauma
基 金:福州市科技计划项目(2022-S-053);福建省创伤骨科急救与康复临床医学研究中心项目(2020Y2014);福州市创伤医学中心(2018080303)。
摘 要:目的通过有限元分析比较肱骨远端后外侧钢板、前方肱骨近端锁定内固定系统(PHILOS)倒置、前方重建钢板固定治疗肱骨干下段骨折的生物力学特性。方法选取1名健康成年男性志愿者,年龄27岁,身高171 cm,体重70 kg。应用有限元法建立肱骨干下段骨折仿真模型,比较肱骨远端后外侧钢板(A组)、前方PHILOS钢板倒置(B组)、前方重建钢板(C组)固定治疗肱骨干下段骨折最大应力和最大位移。结果A、B、C三组模型整体应力峰值分别为409.07、217.04、370.64 MPa;扭转载荷下整体应力峰值分别为234.55、348.80、458.17 MPa;弯曲载荷下整体应力峰值分别为250.22、466.76、582.32 MPa。应力越小说明其疲劳断裂的风险越小。A、B、C三组模型整体位移峰值分别为5.18、3.04、3.75 mm;扭转载荷下整体位移峰值分别为1.20、1.02、2.05 mm;弯曲载荷下整体位移峰值分别为3.85、5.28、9.04 mm。位移越小说明其固定稳定性越好。结论三种内固定比较,PHILOS钢板倒置固定肱骨干下段骨折在轴向压缩、扭转应力下力学稳定性最好,而在弯曲应力下后外侧钢板力学稳定性最好。ObjectiveTo compare the biomechanical properties of posterolateral distal humeral plate,inverted anterior proximal humerus internal locking system(PHILOS),and anterior reconstruction plate in the treatment of distal humeral shaft fractures by a finite element analysis.MethodsOne healthy adult male volunteer,aged 27 years,with a height of 171 cm and a weight of 70 kg,was recruited for this study.The finite element method was used to establish a simulation model of distal humeral shaft fracture.The maximum displacement and maximum stress were compared between fixation with posterolateral distal humeral plate(group A),fixation with inverted anterior PHILOS(group B),and fixation with anterior reconstruction plate(group C).ResultsIn groups A,B,and C,respectively,the overall stress peak values were 409.07 MPa,217.04 MPa,and 370.64 MPa;the peak stresses under torsional load were 234.55 MPa,348.80 MPa and 458.17 MPa;the overall stress peaks under bending load were 250.22 MPa,466.76 MPa,and 582.32 MPa.The smaller the stress,the smaller the risk of fatigue fracture.In groups A,B,and C,respectively,the overall displacement peak values were 5.18 mm,3.04 mm and 3.75 mm;the peak displacements under torsional load were 1.20 mm,1.02 mm and 2.05 mm;the peak displacements under bending load were 3.85 mm,5.28 mm and 9.04 mm.The smaller the displacement,the better the fixation stability.ConclusionsIn the treatment of distal humeral shaft fractures,fixation with inverted anterior PHILOS leads to the best mechanical stability under axial compression and torsional stress,while fixation with the posterolateral distal humeral plate leads to the best mechanical stability under bending stress.
关 键 词:肱骨骨折 骨折固定术 有限元分析 骨板 应力峰值 位移峰值
分 类 号:R318.01[医药卫生—生物医学工程] R683.41[医药卫生—基础医学]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:3.141.35.52