“华龙一号”应急柴油发电机组压缩空气系统设计  

Design of Compressed Air System of the Emergency Diesel Generator Unit Used for HPR 1000

在线阅读下载全文

作  者:侯磊 袁育龙 竺华君 刘栋 郁文钊 薛林涛 HOU Lei;YUAN Yulong;ZHU Huajun;LIU Dong;YU Wenzhao;XUE Lintao(Hudong Heavy Machinery Co.,Ltd.,Shanghai 200129,China;China Nuclear Power Engineering Co.,Ltd.,Shenzhen 518100,Guangdong,China)

机构地区:[1]沪东重机有限公司,上海200129 [2]中广核工程有限公司,广东深圳518100

出  处:《船舶工程》2024年第S02期208-212,共5页Ship Engineering

摘  要:从压缩空气系统在应急柴油发电机组中的重要性出发,结合适用法规、标准及技术规格书特殊要求框架范围,从压缩空气系统功能、系统分级、系统设计要求和设备设计要求等方面综合介绍了“华龙一号”应急柴油发电机组压缩空气系统的设计要求。This article starts from the importance of the compressed air system in the emergency diesel generator unit,combining applicable laws,standards,and special requirements of the technical specification,comprehensively introduces the design requirements of the emergency diesel generator unit's compressed air system from multiple aspects such as the function of the compressed air system,system grading,system design requirements,and equipment design requirements.

关 键 词:华龙一号 应急机组 压缩空气系统 

分 类 号:U671.99[交通运输工程—船舶及航道工程]

 