检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
出 处:《分析试验室》2002年第6期80-82,共3页Chinese Journal of Analysis Laboratory
摘 要:使用X 射线荧光光谱仪 ,采用人工合成标样 ,粉末直接压片和经验系数校正基体效应的方法 ,建立了重整催化剂中铂、铕、铈含量的测定方法。测定铂、铕、铈的相对标准偏差依次为 :0 .5 9%、0 .72 %、0 .75 %。A X ray fluorescence spectrometry was applied to determination of Pt, Eu and Ce in reforming catalyst. The standard samples were manually synthesized, and the powder pellets were used for sample preparation and the matrix effects were corrected by the experience coefficients. The results showed that the accuracy and precision of this method were satisfactory. The relative deviations for Pt?Eu and Ce were smaller than 1 %.
分 类 号:TE624.92[石油与天然气工程—油气加工工程] O64[理学—物理化学]