检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:姜晓峰 JIANG Xiaofeng(Wuling Power Corporation Ltd.,Changsha 410004,China;Hydropower Industry Innovation Center of State Power Investment Co.,Ltd.,Changsha 410004,China;Hunan Province Hydropower Wisdom Engineering Technology Research Center,Changsha 410004,China)
机构地区:[1]五凌电力有限公司,湖南长沙410004 [2]国家电投集团水电产业创新中心,湖南长沙410004 [3]湖南省水电智慧化工程技术研究中心,湖南长沙410004
出 处:《微型电脑应用》2024年第12期76-79,共4页Microcomputer Applications
基 金:国家电投集团自筹科技项目(WL2022-KJ)。
摘 要:针对抽水蓄能机组现有继电保护功能不完善、可靠性较低等问题,提出一种抽水蓄能电站发变电机组智能差动保护控制策略。分析纵联和横联差动保护原理,对于现有频率跟踪算法存在的计算速度慢、准确性偏低等不足,提出基于短数据窗口的频率跟踪算法。结合故障分量电流与全电流差动、零序及负序电流的保护机制,设计一种自适应智能差动保护控制策略。通过算例仿真结果表明,所提策略可以准确、可靠地断开机组内部故障,同时有效避免机组外部故障的误动作。在实际抽水蓄能电站的应用中,所提策略也能够提高继电保护装置动作的可靠性,将故障未可靠动作比例由1.48%降低至0.64%。Aimed at the problems of imperfect function and low reliability of pumped storage units relay protection,an intelligent differential protection control strategy for generation and substation unit of pumped storage power station is proposed in this paper.The principle of longitudinal differential protection and transverse differential protection is analyzed,a frequency tracking algorithm based on short data window is designed to solve the problem of the existing frequency tracking algorithm,such as slow calculation speed and low accuracy.An adaptive intelligent differential protection control strategy is designed,combined with fault component current differential protection,full current differential protection,zero sequence current and negative sequence current protection.The simulation results show that the proposed intelligent differential protection control strategy can accurately and reliably disconnect the internal faults of the unit,and effectively avoid the mis-operation of external faults of the unit.In the practical application of pumped storage power station,the control strategy designed in this paper can improve the action reliability of relay protection device with a reduction in the proportion of the unreliability action from 1.48%to 0.64%.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:3.141.192.51