检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:王献杰 吴爱军[1] 鲁力 田世祥 张英 刘静雯 WANG Xian-jie;WU Ai-jun;LU Li;TIAN Shi-xiang;ZHANG Ying;LIU Jing-wen(School of Environment and Resources,Southwest University of Science and Technology,Mianyang 621010,Sichuan,China;School of Mining and Technology,Guizhou University,Guizhou 550025,China)
机构地区:[1]西南科技大学环境与资源学院,四川绵阳621010 [2]贵州大学矿业学院,贵州550025
出 处:《工程爆破》2024年第6期114-119,共6页Engineering Blasting
基 金:国家自然科学基金资助项目(52104079);西南科技大学研究生创新基金资助项目(24ycx1126)。
摘 要:针对静态破碎剂低温爆破效率低,高温易喷孔的问题,设计并制造一种静态破碎剂加热装置,同时提出相应的控喷方法,即内力平衡法。使用该装置分别在60、80、100℃加热温度下进行静态破碎剂膨胀压力测试,将静态破碎剂水化产物进行X射线衍射分析,对比分析其物象组成,并通过混凝土试件单孔静爆试验验证该装置模拟实际施工的可行性。结果表明:静态破碎剂膨胀压发展分为3个阶段,加热可显著提升静态破碎剂的水化反应速率,其中对第2阶段的影响最明显;加热温度升高,静态破碎剂中氢氧化钙含量剧增。该装置能使静态破碎剂径向膨胀压在5 h内增长至40 MPa,最快可在33 min实现混凝土试件破裂,并且过程中未出现喷孔现象。Aiming at the problems of low blasting efficiency of static crushing agent at low temperature and easy blasting hole at high temperature,a static crushing agent heating device was designed and manufactured,and the corresponding spray control method,namely internal force balance method,was proposed.The device was used to test the expansion pressure of the static crushing agent at the heating temperature of 60℃,80℃and 100℃respectively.The hydration product of the static crushing agent was analyzed by X-ray diffraction,and its image composition was compared and analyzed.The feasibility of the device was verified by the single hole static explosion test of concrete specimen.The results show that the expansion pressure of static crushing agent can be divided into three stages.Heating can significantly improve the hydration reaction rate of static crushing agent,and the influence on the second stage is the most obvious.With the increase of heating temperature,the content of calcium hydroxide in static crushing agent increases sharply.The device can increase the radial expansion pressure of static crushing agent to 40 MPa within 5 h,and the concrete specimen can be broken in 33 min at the earliest,and no spout phenomenon occurs in the process.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:3.141.42.23