Using the principle of dynamic temporal separation to determine the range hood direct capture efficiency  

在线阅读下载全文

作  者:Changsheng Cao Huanjie Huo Yumei Hou Yunfei Xia Chunguang Li Jun Gao 

机构地区:[1]Institute of HVAC,School of Mechanical Engineering,Tongji University,Shanghai 20092,China [2]China United Engineering Corporation Limited,Hangzhou 310052,China

出  处:《Building Simulation》2024年第12期2297-2309,共13页建筑模拟(英文)

基  金:supported by the China National Key R&D Program of the 14th Five-year Plan Period(Grant No.2023YFC3708400);Support from the National Natural Science Foundation of China under Grant No.52208123 in this study is also gratefully acknowledged;supported by the Shanghai Professional Technical Service Platform of Smart and Low-Carbon Controlled Built Environment,Grant No.23DZ2290100.

摘  要:Range hoods are commonly used in residential kitchens to capture pollutants generated during cooking.Direct capture represents the true capture performance of the range hood as a local exhaust device.A better metric for evaluating range hood capture performance is direct capture efficiency(DCE),defined as the ratio of pollutant directly captured by the hood to the total pollutant emission from the source.This paper clarifies the dynamic functioning mechanism of direct capture and reflux capture,analyzes the dynamic characteristics of exhaust concentration,and deduces a simple method for DCE determination based on dynamic temporal separation,where DCE is the ratio of the peak concentration of direct capture(C_(1))to the peak concentration of total capture(C_(2)).Experimental and simulation studies on dynamic exhaust concentration were conducted under different ventilation conditions,and the results were in good agreement.Then,the determination methods of C_(1) and C_(2),including the experimental methods,were further studied to calculate the DCE.The measured and simulated results for DCE based on dynamic temporal separation showed good consistency,with a deviation of less than 2.0%.Finally,the two spatial separation methods for determining DCE(mass flux ratio and virtual purification)proposed and verified in our previous study showed good agreement with the dynamic temporal separation method based on C_(1)/C_(2) proposed here,with a maximum deviation of 2.0%.The determination method of DCE based on dynamic time separation,particularly the experimental method,is of great significance for evaluating the real capture performance of range hoods.

关 键 词:range hoods kitchen ventilation direct capture efficiency local exhaust reflux capture 

分 类 号:R44[医药卫生—诊断学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象