双向CLLC谐振变换器开关管开路故障特性分析  

ANALYSIS OF OPEN-CIRCUIT FAULT CHARACTERISTICS OF SWITCHING TUBE OF BIDIRECTIONAL CLLC RESONANT CONVERTER

在线阅读下载全文

作  者:刘洋 赵鲁[2] 马呈瑶 殷振环 马驰 董侃 Liu Yang;Zhao Lu;Ma Chengyao;Yin Zhenhuan;Ma Chi;Dong Kan(State Key Laboratory for Traction and Control System of EMU and Locomotive,China Academy of Railway Science Corporation Limited,Beijing 100081,China;Key Laboratory of Power Electronics and Electric Drive Institute of Electrical Engineering Chinese Academy of Sciences,Beijing 100190,China;University of Chinese Academy of Sciences,Beijing 100049,China)

机构地区:[1]动车组和机车牵引与控制国家重点实验室(中国铁道科学研究院集团有限公司),北京100081 [2]中国科学院电力电子与电气驱动重点实验室(中国科学院电工研究所),北京100190 [3]中国科学院大学,北京100049

出  处:《太阳能学报》2025年第1期531-539,共9页Acta Energiae Solaris Sinica

基  金:动车组和机车牵引与控制国家重点实验室(中国铁道科学研究院集团有限公司)开放课题基金(2020YJ222);中国国家铁路集团有限公司科技研究开发计划(N2022J016-C)。

摘  要:为研究双向CLLC谐振变换器发生开关管开路故障特性,首先介绍双向谐振变换器CLLC的拓扑与基本原理,分析开关管开路故障后暂态特性6种模态及稳态特性4种故障模式的特点,并利用模态分析法进行建模。在此基础上对CLLC变换器故障后的电压增益、谐振电流应力与谐振电容电压应力进行研究,并与DBSRC变换器发生开关管开路故障时的故障特性进行对比分析。最后,通过仿真与实验验证了故障特性分析的准确性。The bidirectional symmetrical CLLC resonant converter has good soft switching characteristics,wide voltage regulation range,high power density,and broad application prospects.Switch tube open circuit fault is a common fault in power electronic converters.In order to study the characteristics of switch tube open circuit fault in bidirectional CLLC resonant converters,the topology and basic principles of CLLC converters are first introduced.The characteristics of six modes of transient characteristics and four modes of steady-state characteristics after switch tube open circuit fault are analyzed,and modal analysis method is used for modeling.On this basis,the voltage gain,resonant current stress,and resonant capacitor voltage stress of the CLLC converter after failure are studied,and the fault characteristics are compared and analyzed with those of the DBSRC converter when the switch tube open circuit fault occurs.This provides a theoretical basis for the selection of the topology structure of the DC-DC converter for on-board auxiliary converters.Finally,the accuracy of fault characteristic analysis was verified through simulation and experiments.

关 键 词:双向CLLC谐振变换器 开关管开路故障 谐振电流应力 谐振电容电压应力 

分 类 号:TM46[电气工程—电器]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象