既有钢结构工业厂房增设屋顶光伏鉴定与加固中的若干问题研究  

Research on some problems of adding roof photovoltaic in the appraisal ofexisting steel structure industrial plant

在线阅读下载全文

作  者:林于靖 LIN Yujing(Fujian Shangruo Engineering Technology Co.,Ltd.,Xiamen 361000)

机构地区:[1]福建上若工程技术有限公司,福建厦门361000

出  处:《福建建筑》2024年第12期37-39,75,共4页Fujian Architecture & Construction

摘  要:既有钢结构工业厂房,由于其结构体系的特殊性和荷载的敏感性,增设屋顶光伏,对结构的安全性有更高的要求。因此在进行可靠性鉴定、抗震鉴定和加固,已成为此类项目的必要举措。对鉴定分析与加固过程中,在涉及结构安全的年限、荷载和材料等问题进行分析与探讨。Due to the particularity of the structural system and the sensitivity of loads in existing steel structure industrial plants,adding rooftop photovoltaics has higher requirements for the safety of the structure.Therefore,reliability assessment,seismic assessment,and reinforcement have become necessary for such projects.This article analyzes and discusses the setting of calculation parameters such as design life,load parameters,and material strength during the identification.

关 键 词:加固 钢结构厂房 屋顶光伏 可靠性鉴定 抗震鉴定 

分 类 号:TU3[建筑科学—结构工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题