摘 要:某灌区河道泵站增容工程的设计方法为在保留原有泵站的基础上,在河对岸根据设计所需的流量要求新建二号泵站,工程复杂性较高,且场地存在软弱土层和易于渗透破坏的砂性土对工程稳定性影响较大。为保障该工程的安全与质量,本文对其泵站增容设计要点进行阐述并对其稳定性进行详细分析,分析结果表明现有设计方案在抗滑稳定性与抗渗稳定性方面能够满足工程建设需求。本文研究结果对于本工程后续建设工作的开展具有一定指导意义。An irrigation district river pumping station capacity project design method for the retention of the original pumping station on the basis of the river on the other side of the river according to the design of the required flow requirements of the new pumping station No.2,the project complexity is high,and the site there is a weak soil layer and easy to infiltrate the destruction of sandy soils have a greater impact on the stability of the project.In order to protect the safety and quality of the project,this paper on the pumping station capacity increase design points to elaborate and its stability for detailed analysis,the analysis results show that the existing design scheme in the anti-slip stability and seepage stability to meet the needs of engineering and construction.The results of this paper for the subsequent construction of the project has a certain guiding significance.