检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:朱寄天[1] 曾晓荣[1] 张玉[1] 蔡志伟[1] 解景田[2] 谢来华 Zhu Jitian(Research Laboratory of Myocardium Electrophysiology)
机构地区:[1]泸州医学院心肌电生理学研究室 [2]南开大学生物系生理学教研室
出 处:《泸州医学院学报》1988年第1期1-5,共5页Journal of Luzhou Medical College
摘 要:作者使用接触电极记录了在位家兔心脏左室外膜单相动作电位。单相动作电泣在同一部位稳定记录较之以前可达3小时以上。发现接触电极的压力与波形的形态有关,并测量了形成单相动作电位波形的最低压力。当接触电极在心外膜上压迫至25分时,心肌切片显示出组织学改变,但单相动作电位波形并无变化。作者报道了MAP参数:ERP92.97±7.4mS;ERP/APD0.75±0.02;Vmax4.54±1.5V/S。MAP的参数如MAPA、MAPD50、MAPD90与以前的报道相同。The authors employed the contact electrode to record the monophasic action potentials from the left epicardium of rabbits in situ. Long-term, highly stable recording of the monophasic action potentials at the same site lasted as long as two hours or more, We found MAP related to the pressure of the contact electrode. Threshold pressure to form MAP wave was also measured. When the contact electrode had pressed the epicardium for 25 minutes, the myocardal slices showed histologic changes but the MAP wave remained unchanged. The MAP parameters were as follows: ERP, 92.97±7.4mS;ERP/APD, 0.75±0.02;Vmax, 4.54±1.5V/S. The parameters such as MAPA, MAPDand MAPDwere consistent with those in previous reports.
分 类 号:R54[医药卫生—心血管疾病]