电化学法处理炼化污水反渗透浓水实验研究  

Experimental Study on Electrochemical Treatment of Refinery Wastewater by Reverse Osmosis Concentrated

在线阅读下载全文

作  者:李晓旭 徐俊发 刘璐 李晋 Li Xiaoxu;Xu Junfa;Liu Lu;Li Jin(Guangdong Petrochemical Co.,Ltd.,Guangdong,Jieyang,515200;College of Science,China University of Petroleum(Beijing),Beijing,102249;Beijing North Energy Conservation and Environmental Protection Co.,Ltd.,Beijing,100070)

机构地区:[1]广东石化有限责任公司,广东揭阳515200 [2]中国石油大学(北京)理学院,北京102249 [3]北京北方节能环保有限公司,北京100070

出  处:《安全、健康和环境》2025年第1期30-37,共8页Safety Health & Environment

摘  要:炼化污水反渗透浓水具有高盐度、高污染、难生化降解等特性,常规工艺处理难度大。采用电化学法处理炼化污水反渗透浓水,通过单因素实验确定了最佳电化学条件。结果显示:选用锡锑极板和铁板分别为阳极和阴极,硫酸钠为电解质,设置阴阳极面积比为1.5∶1,TOC和TN去除率分别可达46%和35%。进一步优化电化学条件表明:电流密度过大会促进电解水副反应发生,降低有机物降解的电子利用效率;电解质虽然能增加电导率,但是过量添加会降低电极电势,影响有机物在阳极表面的降解效率;碱性体系利于·OH的产生,但pH的增加会导致有机物的矿化产物以CO_(3)^(2-)形式存在,淬灭·OH,降低氧化性能。因此,当电流密度为20.0 mA/cm^(2),SO_(4)^(2-)浓度为9.0 g/L,pH为8.5,电解2.5 h后,出水TOC与TN浓度分别为15 mg/L和14 mg/L,去除率最高,可达56%和55%。实验证明:电化学处理可有效降低炼化污水反渗透浓水污染负荷,减轻常规工艺的处理压力,为实现炼化企业污水零排放提供技术支撑。The reverse osmosis concentrated water from refining wastewater has the characteristics of high salinity,high pollution,and difficult biochemical degradation,making it difficult to treat with conventional processes.The electrochemical method was used to treat concentrated reverse osmosis water from refining wastewater,and the optimal electrochemical conditions were determined through single factor experiments.The results showed that using tin antimony plates and iron plates as anodes and cathodes,sodium sulfate as electrolyte,and setting the anode cathode area ratio to 1.5∶1,the removal rates of TOC and TN could reach 46%and 35%,respectively.Further optimization of electrochemical conditions indicated that excessive current density promoted the occurrence of side reactions in water electrolysis and reduced the electron utilization efficiency of organic matter degradation.Although electrolytes can increase conductivity,excessive addition can lower electrode potential and affect the degradation efficiency of organic matter on the anode surface.The alkaline system was conducive to the production of·OH,but an increase in pH can lead to the mineralization products of organic matter existing in the form of CO_(3)^(2-),quenching·OH and reducing oxidation performance.Therefore,when the current density was 20.0 mA/cm^(2),the SO_(4)^(2-) concentration was 9.0 g/L,the pH was 8.5,and after electrolysis for 2.5 h,the effluent TOC and TN concentrations were 15 mg/L and 14 mg/L,respectively,with the highest removal rates of 56% and 55%.The experimental results showed that electrochemical treatment can effectively reduce the pollution load of reverse osmosis concentrated water in refining wastewater,alleviate the treatment pressure of conventional processes,and provide technical support for achieving zero discharge of wastewater in refining enterprises.

关 键 词:反渗透浓水 电化学 单因素 TOC去除率 TN去除率 

分 类 号:X703.5[环境科学与工程—环境工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象