检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:蒲双红 PU Shuang-Hong(Nanchong Environmental Group Co.,Ltd.,Water Quality Monitoring Center,Nanchong 637000,China)
机构地区:[1]南充环境集团有限责任公司水质监测中心,南充637000
出 处:《实验室检测》2024年第8期86-89,共4页Laboratory Testing
摘 要:总氮,作为水质监测的基础指标,是衡量水体污染程度、自净状况和水体富营养化的重要指标,对于评估水体质量和保护生态环境具有重要意义。本文使用紫外消解分光光度法检测水中总氮对检测过程中的主要影响因素进行探讨,通过对样品自身影响因素、消解过程控制、试剂药品提纯等方法对检测过程进行优化,有效地解决了实验空白过高的问题,提高了检测的可靠性和准确性。Total nitrogen,as a fundamental indicator for water quality monitoring,is an important indicator for measuring the degree of water pollution,self purification status,and eutrophication.It is of great significance for evaluating water quality and protecting the ecological environment.This article explores the main factors affecting the detection process of total nitrogen in water using ultraviolet digestion spectrophotometry.By optimizing the detection process through methods such as sample self influencing factors,digestion process control,and reagent and drug purification,the problem of high experimental blank has been effectively solved,and the reliability and accuracy of the detection have been improved.
分 类 号:X832[环境科学与工程—环境工程]