输电杆塔材料镀锌钢层耐腐蚀性的快速评价探究  

A rapid evaluation method for corrosion resistance of galvanized steel layer for transmission tower materials

在线阅读下载全文

作  者:边美华 彭家宁 何雨茵 李君华 覃宋林 Bian Meihua;Peng Jianing;He Yuyin;Li Junhua;Qin Songin(Electric Power Research Institute of Guangxi Power Grid Co.,Ltd.,Nanning 530023,China;Guangxi Key Laboratory of Intelligent Control and Maintenance of Power Equipment,Nanning 530023,China)

机构地区:[1]广西电网有限责任公司电力科学研究院,广西南宁530023 [2]广西电力装备智能控制与运维重点实验室,广西南宁530023

出  处:《电镀与精饰》2025年第2期54-60,共7页Plating & Finishing

基  金:广西电网科技项目(GXKJXM20230096)。

摘  要:输电杆塔是输电线路的重要部分,它在服役过程中需要承受诸多荷载,特别是在工业区和沿海地区,输电杆塔材料的腐蚀问题尤为突出,产生了极大的安全隐患。采用自制的定点腐蚀装置及室内浸泡腐蚀试验方法,将镀锌钢表面的锌镀层在酸性腐蚀溶液中溶解,游离出的亚铁离子(Fe^(2+))被氧化剂氧化为Fe^(3+);通过Fe^(3+)与磺基水杨酸(SSal)发生显色反应,利用分光光度计在线检测溶液中的Fe^(3+);通过游离出Fe^(3+)所需要的时间来评价镀锌层的耐腐蚀性能;利用扫描电镜(SEM)和X射线衍射仪(XRD)分析镀锌钢表面腐蚀产物的形貌和组成。结果显示:腐蚀溶溶pH=1.0~3.0时,可在3 h内评价镀锌钢的耐腐蚀性能,该研究为输电杆塔的合理选材和预测材料寿命提供了重要参考。Transmission tower is an important part of the transmission line,it needs to bear a lot of load in the service process,especially in industrial areas and coastal areas,the corrosion of transmission towe materials is particularly prominent,resulting in great security risks.The corrosion behavior of galvanized layer on the surface of galvanized steel structural parts of power grid equipment was studied by using a self-made fixed point corrosion device and indoor immersion corrosion test method.The zinc coating on the surface of galvanized steel was dissolved in acid corrosion solution,and the free ferrous ions(Fe^(2+))were oxidized to Fe^(3+)by oxidants.The chromogenic reaction of Fe^(3+)with sulfosalicylic acid(SSal)wa carried out to detect Fe^(3+)in the solution by spectrophotometer.The corrosion resistance of galvanized layer was evaluated by the time required for Fe^(3+)ionization.The surface corrosion morphology and composition of corrosion product of galvanized steel were studied by scanning electron microscopy(SEM)and X-ray diffractometer(XRD).The results show that when the pH of corrosion solution is 1.0-3.0,the corrosion resistance of the galvanized steel plate commonly used in the market can be evaluated within 3h.This study provides an important reference for reasonable material selection and material life prediction of transmission tower.

关 键 词:镀锌钢 快速评价 耐腐蚀性能 分光光度法 

分 类 号:TQ139.1[化学工程—无机化工]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象