某H级燃气轮机启动失败原因分析  

Analysis of starting failure of a class H gas turbine

在线阅读下载全文

作  者:陈乾彬 CHEN Qianbin(Eastern power plant of Shenzhen Energy Group Co.,Ltd.,shenzhen 518120,China)

机构地区:[1]深圳能源集团股份有限公司东部电厂,广东深圳518120

出  处:《中国高新科技》2024年第23期50-51,54,共3页

摘  要:燃气轮机组其快速启停特性,非常有利于电网进行调峰和调频,且其燃料主要为天然气等清洁能源,排放污染物较小。因此,在需调峰调频的城市,大型燃气轮机的安全启停是极其重要的。文章针对某次西门子H级重型燃气轮机因SFC起动失败而导致燃机启动失败的故障原因进行了详细分析和解决办法,为同类电厂提供相关经验和借鉴依据。The fast start-stop characteristics of gas turbine units,very conducive to the power grid for peak regulation and frequency modulation,and its main fuel for natural gas and other clean energy,emission of pollutants less.Therefore,it is very important to start and stop large gas turbines safely in cities that need peak shaving and frequency regulation.In this paper,the failure causes of a Siemens h-class heavy-duty gas turbine due to SFC start-up failure are analyzed in detail.

关 键 词:燃机 SFC 励磁 定冷水温 冷氢温度 原因分析处理 