空调换热器翅片凝露仿真分析  

Simulation analysis of condensation on air conditioning heat exchanger fins

在线阅读下载全文

作  者:司义军 谷伟 刘丽影 Si Yijun;Gu Wei;Liu Liying(School of Metallurgy,Northeastern University,Shenyang 110819,China;Guangdong Midea Refrigeration Equipment Co.Ltd.,Foshan 528311,China)

机构地区:[1]东北大学冶金学院,沈阳110819 [2]广东美的制冷设备有限公司,佛山528311

出  处:《低温与超导》2025年第1期48-56,共9页Cryogenics and Superconductivity

基  金:国家自然科学基金(22078054);广东省基础与应用基础研究基金区域联合基金项目(2022A1515140087)资助。

摘  要:本文通过数值模拟,研究了湿工况下具有相同表面积的三种家用空调常用翅片的表面传热传质特性。分析了不同空气入口速度和相对湿度条件下,三种翅片的换热量、压降、效率指数,获得了翅片表面液滴凝结分布情况。研究结果显示,在相同表面积条件下,百叶窗翅片在效率指数方面表现出更为优越的性能。实验值与模拟值的误差在10%以内,验证了模型具有较高的准确性。The surface heat and mass transfer characteristics of three commonly-used fins were studied through numerical simulation in household air conditioners with the same surface area under wet conditions.The heat transfer rate,pressure drop,and efficiency index of the three fins under different air inlet velocities and relative humidity conditions were analyzed,and the distribution of liquid droplet condensation on the fin surface was obtained.The research results show that under the same surface area conditions,the louver fin exhibits superior performance in terms of the efficiency index.The error between the experimental values and the simulation values is within 10%,verifying the high accuracy of the model.

关 键 词:翅片管式 换热器 湿工况 热质传递 阻力特性 

分 类 号:TB657.2[一般工业技术—制冷工程]

 